MULTISETWORKS OPERATION (OPTIONAL EQUIPMENT)
Errors
MULTISETWORKS OPERATION (OPTIONAL EQUIPMENT)Multisetworkdoc012819
3-21
3
See Figure 3-25.
3.7.5 Impulses are not counted.
See Figure 3-26.
This error may be caused by damage of: encoder, clutch between encoder and motoreducer, wire
connecting encoder and connectors or wires connecting PLC controller inputs and power supply with
connectors.
First remove encoder cover and check if encoder clutch is tightened and is not damaged.
Next, check the encoder connection to PLC controller or OTB module (encoders of the saw head
number 1 and 2 are connecting with PLC 1.0 controller; encoders of the saw head number 3 and 4 are
FIG. 3-25
FIG. 3-26