Maintenance
Ceramic Guide Disks
Maintenance
HD97doc041910
5-7
5
3.
Make sure the blade screw in the top center of the C-frame is 1/16" (1.5 mm) away from
the blade. If not, loosen the nut and adjust the screw as necessary. Check the screw
every 500 hours of operation. Failing to maintain this adjustment will lead to early blade
breakage.
See Figure 5-4.
FIG. 5-4
SM0054
1/16“ (1.6 mm)