Troubleshooting Guide
Simple Set PID Settings
6
6-13
WMdoc072619
Troubleshooting Guide
6.
Use the Up/Down arrow buttons to set the InvGear setting to the required value as shown
in the table above.
7.
Press the Manual button to return to the main menu.
Simple Set PID Settings
1.
Make sure the power to the control box is on.
2.
Press and hold the Manual button and then press and hold the UP arrow. Release the
Manual button, then release the UP arrow. The Simple Set control panel will display the
Speed setting.
See Figure 6-7.
3.
Press the Auto button several times until PGain, DGain and IGain settings appear. Use
the Up/Down arrow buttons to set the settings to the required values.
IMPORTANT!
The
PID settings are factory-set and they should not be changed. If necessary, set the PID
settings to the following values: PGain 1.0, DGain 0.0 and IGain 0.0.
4.
Press the Manual button to return to the main menu.
Simple Set Troubleshooting (LT35)
Follow the instructions below to solve the possible power feed problems.
If the saw head does not go up or down:
Disconnect the wires to the up/down motor,
Jump a volt meter or test light across the two wires going back to the control box,
With the key/toggle switch on, put the drum switch/joystick in the up position,
If there is a 12VDC reading, check for stuck or worn motor brushes or replace
motor.
FIG. 6-7
3H1128
Scroll Up/Down
Display
Manual
Auto