Setup & Operation
Sawmill Setup
2
2-1
HDdoc012020
Setup & Operation
SECTION 2 SETUP & OPERATION
2.1
Sawmill Setup
IMPORTANT!
Before starting to use the sawmill you have to meet the
following conditions:
Set up the sawmill on firm, level ground and level the sawmill. Secure the sawmill to the
ground to prevent moving during operation. A concrete foundation or pads (rated to support
31 T/m
2
at each sawmill foot position) and 16mm anchored bolts are recommended.
It is not allowed to use the sawmill indoor. When using this sawmill type outdoor it is allowed
to work without sawdust collection system connected. We recommend to setup sawmill in
the way that operator position be down the wind. It will separate the operator from sawdust
and engine exhaust gases
The sawmill can be operated in temperature range from -15
o
C to 40
o
C only.
Illuminance at operator's position must be 300lx.
!