Maintenance
Blade Tensioner
Maintenance
WMdoc072919
5-9
5
See Figure 5-7.
4.
Grease the clamp mechanism, loading arm, and side support pivots with a NLGI No. 2
grade lithium grease every fifty hours of operation.
5.
Check the mill alignment every setup (
6.
Ensure all safety warning decals are readable. Replace any damaged or unreadable
decals immediately. Order decals from your Customer Service Representative.
5.8
Blade Tensioner
WARNING!
Before performing service near moving parts such as
blades, pulleys, motors, belts and chains, first turn the key switch to
the OFF (0) position and remove the key. Failure to follow this could
result in death or serious injury.
LUBRICATE
1.
Lubricate the chrome rods of the tensioner system with a heavy duty teflon spray lubri-
cant, such as Gunk L508, every fifty hours of operation.
2.
Lubricate the tensioner screw handle with a NLGI No. 2 grade lithium grease as needed.
FIG. 5-7
LX0006-10
Blade guide
arm chain
50
50