SETUP & OPERATION
Multi-Planer Setup
3
3-2
EGdoc052521
See table 3-1.
Have a qualified electrician install the power supply (according to EN 60204
Standard). The power supply must meet the specifications given below.
IMPORTANT!
It is recommended that a 30mA GFI (Ground Fault
Interrupter) be used.
IMPORTANT!
When starting the machine for the first time, check that
the main motor rotation direction is as indicated by the arrow located
on the motor body (fan guard). If the rotation direction is incorrect,
invert the phases in the phase inverter in the power socket (electrical
box). Setting the phases in the phase inverter correctly will ensure
correct rotation directions of all motors.
WARNING!
If the drive belt breaks, wait until all rotating parts are
completely stopped. Failure to do so may result in serious injury or
death.
DANGER!
To check the cutter rotation direction, look at the cutter or
motor fan when the Multi-Planer is turning on or off. Do not check the
cutter rotation direction by touching the cutter by hand or with any tool.
Failure to do so will result in serious injury of death.
BEFORE STARTING:
Mount the control box using M8x20 socket head screws (A), washers and nuts (B).
3-Phase
Volts
Fused Disconnect
Switch
Suggested Wire Size
400 VAC
16 A
1.5 mm
2
Max. length: 15 m
TABLE 3-1
!
!