INTRODUCTION
Chip Extractor
1
1-5
doc071420
INTRODUCTION
These spacer rings are necessary to set the required height.
1.2
Chip Extractor
MP360 planer/moulder must be connected to chip extractor with a capacity of at least 5 000m
3
/h.
Remember that chip container has to be equipped with an air vent (e.g. a fine net or filter if dust are
collected indoors). During work in heated rooms, it is necessary to remember that the fan will quickly
cool the space if the filtered air will not be supplied back into the building.
Contact the local authorities for advice in designing a chip collection system to conform with national
rules.
It is necessary to set the fan so that it will be easy to reach the switch.
IMPORTANT!
Remove the chips from the planer/moulder when the
work is finished.
CHIP EXTRACTOR TECHNICAL REQUIREMENTS
1
The chip extractor must be approved according to the CE-standard.
The airflow "without external connection" must be approx. 5000 m3/hour. (The manufacturer's
standard indication of airflow.)
The chip extractor hose diameters for the planer/moulder = 100 mm (4”) x 3 and 125 mm (5”) x
1.
Pressure drop should not exceed 1,5 kPa.
IMPORTANT!
The dust extractor hoses must be grounded or made
with materials not accumulating electrostatic charge.
CAUTION!
Always turn on the chip extractor before starting the
machine
1. EN 12779:2016-04 standard contains requirements for chip and dust extraction systems equipment with
fixed installations.
!
!