15
An ongoing program of product improvement may require us to change
specifications without notice.
MH-RFG-W
Revised November 2009
Wood Stone Corporation
1801 W. Bakerview Rd.
Bellingham, WA 98226 USA
Toll Free (800) 578-6836
Tel (360) 650-1111
Fax (360) 734-0223
Info@woodstonehome.com
or visit
www.woodstonehome.com
Mountain Series Installation and Operation Manual
aSSemBLY
ASSEMBLY
1.
Mount the appliance mantle (if provided) using the hardware provided. (See figure on
page 16
).
2.
Mount the stainless steel toe kick to the front of the stand, near the floor using the hardware provided (See figure on
page 17
). If your appliance was shipped with a lower facade extension there is no toe kick required.
3.
Mount the service/intake panel to the brackets on the front of the stand, directly below the doorway, using the hardware
provided (See figure on
page 17
, if your appliance was shipped with the optional facade extensions,
page 18
).
a.
Do not obstruct the flow of combustion and ventilation air between the toe kick and the bottom of the service/
intake panel.
b.
This panel is the only access for servicing the gas and electrical components of the appliance so it must be left
accessible and removable.
4.
The following applies to stucco finish appliances only (Models ending with S):
a.
Once the appliance has been set in place, cover wire mesh and metal lathing with no less than 1 inch of stucco
(see
page 19
for diagram).
ASSEMBLY