PREVENTIVE MAINTENANCE
An ongoing program of product improvement may require us to change
specifications without notice.
SFR, Revised November 2014.
Doc no: M0057.02
info@woodstone-corp.com
or visit
woodstone-corp.com
wood stone corporation
1801 w. bakerview rd.
bellingham, wa 98226 usa
tf. 800.988.8103
t. 360.650.1111
f. 360.650.1166
Contact the Wood Stone Service Department or a qualified local service company for any maintenance or repairs.
NOTE:
ALWAYS DISCONNECT POWER SUPPLY BEFORE SERVICING THIS APPLIANCE.
MAIN BEARING LUBRICATION (EVERY 12 MONTHS)
The two main shaft bearings should receive one pump of a NLGI Grade 2 lithium-based grease, such as Lubriplate 630-2, every
12 months. These bearings are located inside the cabinet on either end of the main shaft. A Zerk fitting for each bearing is located
directly below the top door hinge on either side of the cabinet on the operator (door) side. Care should be taken not to over lubricate
these bearings. One pump is sufficient.
MOTOR BRUSHES REPLACEMENT (APPROXIMATELY EVERY 3 YEARS)
The three year replacement recommendation is based upon an average daily use of 10 hours. Contact the Wood Stone Service
Department or your local service technician for service.
REDUCTION GEAR LUBRICATION
The gearbox is permanently lubricated and requires no additional maintenance.
SPUR GEAR BUSHING
Check the spur gear bushings for signs of binding or lateral movement where the gear shank passes through the drive end drum.
The gear should rotate in the Rulon inner bushing. If the gear and Rulon bushing are rotating in the drum sleeve instead, remove
the gears and Rulon bushings, clean and refit. Do not lubricate the bushings or gears. To remove the gears, first mark the drum in
relation to the shaft to ensure it is reinstalled in the same position. Remove the six bolts that retain the drum end to the hub and slide
the drum end assembly toward the center of the cabinet. The spur gears can now be removed by loosening the set screw retaining
the locking collar and sliding the gears out of the drum.
INNER DRUM SEALING
The condition of the high-temperature sealant used to seal the inner drums to the cabinet walls and the inside corners of the cabinet
should be checked and renewed if sealant has failed. Use Dow Corning 732 RTV sealant.
DOOR JAMB MICRO SWITCH
Check the jamb switch for proper operation. The switch should move freely in the jamb without sticking or binding and the drums
should stop when the doors are opened.
SPEED CONTROL KNOB
Check the speed control potentiometer for proper operation and the knob for tightness.
DOOR LATCH
Check the door latch mechanism for proper operation. If sticking occurs, remove the wedge pin, clean, refit and adjust.
EXHAUST HOOD
Refer to the exhaust hood manufacturer’s recommendations for inspection, maintenance and cleaning.