Cascade Gas-Fired Rotisserie & Charbroiler
Installation and Operation Manual
6
An ongoing program of product improvement may require us to change
specifications without notice.
WS-GFR-MB, Revised November 2014.
Doc no: M0050.01
info@woodstone-corp.com
or visit
woodstone-corp.com
wood stone corporation
1801 w. bakerview rd.
bellingham, wa 98226 usa
tf. 800.988.8103
t. 360.650.1111
f. 360.650.1166
SPECIFICATIONS
VENT AREA
4"
100mm
47"
1190mm
11"
280mm
37"
940mm
28"
710mm
23"
580mm
52 1/2"
1330mm
25"
640mm
37"
940mm
74"
1880mm
78 1/4"
1990mm
44"
1120mm
28 1/2"
720mm
23"
580mm
4"
100mm
47"
1190mm
11"
280mm
24"
610mm
44"
1120mm
28 1/2"
720mm
14"
360mm
9"
230mm
72 1/2"
1840mm
11"
280mm
51"
1300mm
11 1/2"
290mm
48"
1220mm
2 1/2"
60mm
4"
100mm
47"
1190mm
11"
280mm
62"
1570mm
23"
580mm
37"
940mm
8"
200mm
G
C
GD
3/4" NPT, 175,000 BTU, NG
185,000 BTU, LP
G
C
GD
115 VAC, 5A
WATER SUPPLY 1/4" N.P.T.
GREASE DRAIN 1 1/2" SLIP FIT
1
1
1" NPT, 152,000 BTU, NG
152,000 BTU, LP
G
2
G
2
VENT AREA
4"
100mm
47"
1190mm
11"
280mm
37"
940mm
28"
710mm
23"
580mm
52 1/2"
1330mm
25"
640mm
37"
940mm
74"
1880mm
78 1/4"
1990mm
44"
1120mm
28 1/2"
720mm
23"
580mm
4"
100mm
47"
1190mm
11"
280mm
24"
610mm
44"
1120mm
28 1/2"
720mm
14"
360mm
9"
230mm
72 1/2"
1840mm
11"
280mm
51"
1300mm
11 1/2"
290mm
48"
1220mm
2 1/2"
60mm
4"
100mm
47"
1190mm
11"
280mm
62"
1570mm
23"
580mm
37"
940mm
8"
200mm
G
C
GD
3/4" NPT, 175,000 BTU, NG
185,000 BTU, LP
G
C
GD
115 VAC, 5A
WATER SUPPLY 1/4" N.P.T.
GREASE DRAIN 1 1/2" SLIP FIT
1
1
1" NPT, 152,000 BTU, NG
152,000 BTU, LP
G
2
G
2
Plan view
Shown: Left-side drive
Rear view
(determines drive side)
Front view
UTILITIES SPECIFICATIONS
Rotisserie Gas:
1 inch FNPT gas inlet
175,000 BTU/hr Natural Gas (NG) OR
185,000 BTU/hr Propane (LP)
Broiler Gas:
1 inch FNPT gas inlet
152,000 BTU/hr Natural Gas (NG)
OR Propane (LG)
Maximum gas inlet pressure
1/2 psi (14 inches W�C�)
Electrical
120 VAC, 5 A, 50/60 Hz
Water
Inlet: 1/4" FNPT
Drain: 1-1/2" outlet tube
All utility connections made on the bottom
of the unit� NEMA 5-15 plug
Refer to data plate when installing�
Shipping
Weight:
2,000 lbs
�
Venting
The Cascade Rotisserie must be vented
using a Listed Type 1 exhaust hood, or
one constructed in accordance with NFPA
96 and all relevant local and national
codes, and in a manner acceptable to the
authority having jurisdiction�
1
2
VENT AREA
4"
100mm
47"
1190mm
11"
280mm
37"
940mm
28"
710mm
23"
580mm
52 1/2"
1330mm
25"
640mm
37"
940mm
74"
1880mm
78 1/4"
1990mm
44"
1120mm
28 1/2"
720mm
23"
580mm
4"
100mm
47"
1190mm
11"
280mm
24"
610mm
44"
1120mm
28 1/2"
720mm
14"
360mm
9"
230mm
72 1/2"
1840mm
11"
280mm
51"
1300mm
11 1/2"
290mm
48"
1220mm
2 1/2"
60mm
4"
100mm
47"
1190mm
11"
280mm
62"
1570mm
23"
580mm
37"
940mm
8"
200mm
G
C
GD
3/4" NPT, 175,000 BTU, NG
185,000 BTU, LP
G
C
GD
115 VAC, 5A
WATER SUPPLY 1/4" N.P.T.
GREASE DRAIN 1 1/2" SLIP FIT
1
1
1" NPT, 152,000 BTU, NG
152,000 BTU, LP
G
2
G
2
VENT AREA
4"
100mm
47"
1190mm
11"
280mm
37"
940mm
28"
710mm
23"
580mm
52 1/2"
1330mm
25"
640mm
37"
940mm
74"
1880mm
78 1/4"
1990mm
44"
1120mm
28 1/2"
720mm
23"
580mm
4"
100mm
47"
1190mm
11"
280mm
24"
610mm
44"
1120mm
28 1/2"
720mm
14"
360mm
9"
230mm
72 1/2"
1840mm
11"
280mm
51"
1300mm
11 1/2"
290mm
48"
1220mm
2 1/2"
60mm
4"
100mm
47"
1190mm
11"
280mm
62"
1570mm
23"
580mm
37"
940mm
8"
200mm
G
C
GD
3/4" NPT, 175,000 BTU, NG
185,000 BTU, LP
G
C
GD
115 VAC, 5A
WATER SUPPLY 1/4" N.P.T.
GREASE DRAIN 1 1/2" SLIP FIT
1
1
1" NPT, 152,000 BTU, NG
152,000 BTU, LP
G
2
G
2
Side view
The only difference between the GFR-6-MB and GFR-10-MB is the number of spits. All other dimensions are the same.
See page
17 for spit
placement
dimensions.