11
Circular Grill–1500
Installation and Operation Manual
An ongoing program of product improvement may require us to change
specifications without notice.
WS-LHPCGG-D-1500-C Circular Grill,
Revised June 2015. Doc no: M0017.01
info@woodstone-corp.com
or visit
woodstone-corp.com
Wood Stone Corporation
1801 W. Bakerview Rd.
Bellingham, WA 98226 USA
Toll Free 800.988.8103
Tel 360.650.1111
Fax 360.650.1166
UTILITY INFORMATION
The Circular Grill is equipped with a 3/4" NPT gas inlet connection� Have a licensed gas installer provide the hook-up and test all
fittings and pipe connections for leaks� Use approved gas leak detectors (soap solutions or equivalent) over and around the fittings
and pipe connections�
DO NOT USE A FLAME TO TEST FOR LEAKS!
Wood Stone recommends that a manual, individual appliance shutoff valve be supplied, located between the rotisserie and the main
gas supply, and be left readily accessible�
BURNER PRESSURE TESTING
There are (2) pressure test ports (one for each burner), located on the respective valves� The valve outlet pressures have been
adjusted and tested at the factory� A variety of factors can influence these pressures, so be sure to test the valve outlet pressures
and adjust the valves as necessary to achieve the suggested pressures�
NOTE:
The gas valves are shipped in the ON position�
MANIFOLD PRESSURE / GAS RATING
Natural Gas (NG): 4.0" W.C.
250,000 BTU/hr
Propane (LG): 10.0" W.C.
265,000 BTU/hr