4)   Connect Power Supply: 

Connect power supply to control unit. The electrical connec ons must comply with local 

authority regula ons and must be done by an authorized electrician.  

5)   Fill bathtub with water to approximately 40 mm(1.6

˝

) above the jets and trial run pump for 

      10-15 minutes. Check all the 

fi

ngs for leaks and test the control func ons. Switch o

 the 

      spa pump and leave the unit 

fi

lled with water (pump is not running) for at least another two 

      minutes. Check the pump and pipes union connec ons for leaks. Hand  ghten union 

      connec ons if required.       

IMPORTANT:  Your bathtub has been factory tested and  approved. It is the responsibility of 

the installer to test run the bathtub, check all the 

fi

ngs for leaks and test the control func ons. 

NON OBSERVANCE WILL INVALIDATE FACTORY WARRANTY. 

6)   The unit must be connected only to a supply circuit that is protected by a Ground-Fault 
       Circuit Interrupter (GFCI). Such a GFCI should be provided by the installer and should be 

       tested on a rou ne basis.

3)  Set the bathtub on two 4x4 pieces of lumber .so you can access from the bo om  of the bathtub.    

R

1 Total Breakers

Air  Blower 

RES

ET

CGFI

Outlet

RESET

120V 15AMP
Dedicated
GFCI Breaker

In the example above, there are 1 Dedicated 15AMP 110V GFCI Breakers.

 

 

1.  One (1) Dedicated GFCI Breaker for the Air Massage Blower 

Each Accessory Requires a Dedicated 120V 15AMP GFCI Breaker.

THESE CANNOT BE SHARED

(LED LIGHTS & OZONE CAN SHARE A BREAKER)

AIR MASSAGE

B 0 0 3 1 / B T S 1 6 0 7           B 0 0 3 3 / B T S 1 6 1 0

ELECTRICAL REQUIREMENTS

R

WOODBRIDGE 

WHIRLPOOL & AIR BATHTUB

Summary of Contents for B0030

Page 1: ...s may vary from state to state in accordance to your loca on We are not responsible for providing any compliance cer fica ons Under no circumstances we shall not be liable for any incidental damages s...

Page 2: ...read all opera ng and safety instruc ons All informa on is based on the latest product informa on available at the me of publica on WOODBRIDGE reserves the right to make changes in product characteri...

Page 3: ...bing Preparation Posi on the plumbing according to rough in dimensions Cap the supplies and check for leaks BEFORE INSTALLING UNIT CAUTION Ensure a watertight seal on the bath drain connections A Inst...

Page 4: ...ibility of the installer to test run the bathtub check all the fi ngs for leaks and test the control func ons NON OBSERVANCE WILL INVALIDATE FACTORY WARRANTY 6 The unit must be connected only to a sup...

Page 5: ...GFCI Breakers 1 One 1 Dedicated GFCI Breaker for the Whirlpool Pump 2 One 1 Dedicated GFCI Breaker for the Air Massage Blower Each Accessory Requires a Dedicated 120V 15AMP GFCI Breaker THESE CANNOT...

Page 6: ...ww woodbridgebath com 5 NOTES DATE OF INSTALL INSTALLER S NAME PLUMBER CONTRACTOR LICENSE INSTALLER INFORMATION NOTES DATE OF INSTALL INSTALLER S NAME PLUMBER CONTRACTOR LICENSE INSTALLER INFORMATION...

Page 7: ...be installed by a fully insured and licensed contractor only Installa on by anyoneother than fully insured and licensed contractorwillvoid this limited warranty This warranty does not cover surface d...

Page 8: ...tore shine Repeat as needed un l surface shine is restored Repair and Maintenance The bathtub must be installed and used as described in this manual Use cau on when entering or exi ng the bathtub Do n...

Reviews: