background image

R

WOODBRIDGE 

R

WOODBRIDGE 

R

WOODBRIDGE 

R

WOODBRIDGE 

R

WOODBRIDGE 

R

WOODBRIDGE 

R

WOODBRIDGE 

R

WOODBRIDGE 

www.woodbridgebath.com

BEFORE YOU BEGIN 

PRODUCT REQUIREMENTS 

A. Summary Of Key Requirements 

 Observe all local plumbing codes, Install the unit to a level sub

fl

oor,Provide properly

 -dimensioned framing.    

B. Product Inspection 

Uncrate and inspect bath for damage. Leave all materials in the crate during construc on to 

prevent damage.

ROUGHING-IN 

 

 

2

•  All informa on is based on the latest product informa on available at the  me of 

publica on. WOODBRIDGE

® 

 reserves the right to make changes in product 

characteris cs, packaging, or availability at any  me without no ce. 

 •  Please read these instruc ons carefully to familiarize yourself with the required 
     tools, materials, and installa on sequences. Follow the sec ons that pertain to your 

     par cular installa on. This will help you avoid costly mistakes. In addi on to proper 
     installa on, read all opera ng and safety instruc ons. 

IMPORTANT     INFORMATION 

• Measurements are ± 1/2" and subject to change without no ce 
• Speci

fi

ca ons & Con

fi

gura ons are subject to change without no ce

• Please measure tub on-site before installa on

 • Please note that installer(s) must be cer

fi

ed or warranty will be voided.

 • Measurements herein supersede all others published prior to purblica on
   date shown below
 • Before ordering or installing, please consider future access to equipment

B 0 0 9 1 / B T S 0 0 9 1

Control box

15"

Water depth

47 1/4"

35 3/8"

45 5/8"

70 7/8"

23 5/8"

27 1/2"

Air  Blower
  (0.3KW) 

B 0 0 9 2 / B T S 0 0 9 2

26 3/4"

23 5/8"

31 1/2"

20"

41 3/4"

67"

15"

Water depth

Control box

47 1/4"

37 3/4"

45 5/8"

70 7/8"

26 3/8"

23 5/8"

14 7/8"

Water depth

 Heater 
(1.5KW)

Hydromassage 
Pump (1.1KW) 

Air  Blower
  (0.3KW) 

Control box

6 5/8"

B 0 0 9 0 / B T S 0 0 9 0

Hydromassage 
Pump (1.1KW) 

Heater 
(1.5KW)

Air  Blower
  (0.3KW) 

Hydromassage 
Pump (0.75KW) 

Heater 
(1.5KW)

Summary of Contents for B0090

Page 1: ...oviding any compliance cer fica ons Under no circumstances we shall not be liable for any incidental damages sustained in connec on with this product Neither manufacture nor distributor nor retailer i...

Page 2: ...ll help you avoid costly mistakes In addi on to proper installa on read all opera ng and safety instruc ons IMPORTANT INFORMATION Measurements are 1 2 and subject to change without no ce Specifica ons...

Page 3: ...ng Preparation Posi on the plumbing according to rough in dimensions Cap the supplies and check for leaks BEFORE INSTALLING UNIT CAUTION Ensure a watertight seal on the bath drain connections A Instal...

Page 4: ...factory tested and approved It is the responsibility of the installer to test run the bathtub check all the fi ngs for leaks and test the control func ons NON OBSERVANCE WILL INVALIDATE FACTORY WARRA...

Page 5: ...en it Adjust it to be level Reconnect 1 Voltage HZ needs match up with the product s parameter 2 Power supply needs a good grounding 3 The pressure of water supply needs meet 0 2 0 4Mpa 4 The Whirlpoo...

Page 6: ...unc on switch valve E uent Shower Cold water pipe 1 5m Hot water pipe 1 5m Hot Cold GROUND NEUTRAL L1 THE LEAKAGE SWITCH L1 NEUTRAL GROUND The control panel Force regula ng valve Display window Switch...

Page 7: ...R OODBRIDGE WOODB R OODBRIDGE WOODB OODBRIDGE WOODB www woodbridgebath com 7 Service Access Door Service Access Door Tub Rim Service Access Door LED light indicator...

Page 8: ...reference a er installa on Please contact your local authorize dealer or call our customer service support for any assistance with opera on or maintenance related ques on OPERATION TIPS 1 Unplug the...

Page 9: ...ter level detec on Child Keypad Lock Touch Sensor technology 2 Control system Keypad x1 Control Box x1 3 Control Box Specifica on Voltage AC110V Hertz 60 Hz Consume Voltage 25A Standby Rate 1W Working...

Page 10: ...perature on LCD screen Display will blink if it is not equipped with Press and hold Power Func on bu on for 3 seconds to power o the unit 3 CHILD Keypad Lock The unit is On and no ac vity on the keypa...

Page 11: ...quence indictor will be blinking Current temperature Water Pump Timer for water pump Defaulted temperature Air Blower Constant heated LED lightson bo om Note 1 Default opera ng me for water pump is 45...

Page 12: ...to disassemble or modify any of the wiring or unplug and reconnect the wire when it Power box is s ll with power 7 The wiring and connec on on power box must match with the diagram output cannot be sh...

Page 13: ...ts should be installed by a fully insured and licensed contractor only Installa on by anyoneother than fully insured and licensed contractorwillvoid this limited warranty This warranty does not cover...

Page 14: ...ets are closed Suc on cover strainer may be clogged Open jets by rota ng counter clockwise with the motor turned OFF remove the suc on cover strainer and remove any debris Replacethe suc on cover befo...

Page 15: ...shine is restored Repair and Maintenance The bathtub must be installed and used as described in this manual Use cau on when entering or exi ng the bathtub Do not permit children or persons with infir...

Reviews: