Date: 21/7/2022
Version Number: 2022 Issue no.3
Page
36
Declaration of performance according to Regulation (EU) 305/2011
Ref No: FL-Lowry5X-CPR-2021-01
Point
Product Type
Flue & Ducting room heater burning solid fuel without supply of
hot water in accordance with EN 13240:2001
1
2
Product model designation
Lowry 5X, Serial No. -
3
Intended use
Room heater burning solid fuel without supply of hot water
4
Manufactured by
Flue & Ducting
Unit D6 Yew Street Stockport Trading Estate SK4 2JZ
Tel: +44 0161 480 2994 Fax:
Email: sales@flue-ducting.co.uk
5
Manufacturer’s authorized representative
6
System of assessment and verification of
constancy of performance
System 3
7
Notified laboratory name and address
The notified laboratory SGS Nederland B.V., Laboratory number
608 performed the determination of the product type
specification on the basis of type testing under system 3 and
issued the test report Ref: EZKA/2019-06/00015-3A
8
Declared performance: -
Harmonized Technical
specification:
EN 13240:2001
Essential characteristics
Performance – Wood
Performance - Ancit
Fire Safety: -
Reaction to fire
A1
Clearance distances to
combustible materials
Rear = Non-Combustible
Sides = 600mm
Ceiling = NPD
Risk of burning fuel falling out
PASS
Emission of combustion products
CO = 0.11%
CO=0.08%
Surface temperatures
PASS
PASS
Electrical safety
N/A
N/A
Cleanability
PASS
PASS
Maximum operating pressure
N/A
N/A
Flue gas temperature at nominal
heat output
196 °C
225 °C
Mechanical resistance to carry a
chimney
NPD
NPD
Nominal output
4.9kW
4.9kW
Room heating output
4.9kW
4.9kW
Water heating output
Gross efficiency
75.7%
85.0%
Net Efficiency
83.2%
86.7%
9
The performance of the product identified in points 1 and 2 is in conformity with the declared performance
given in point 8.
Signed for and on behalf of the manufacturer by:
(Name)
(Date of issue)
(Signature)