A. Brick Masonry
Minimum
3.5˝/89mm
thick brick masonry all framed into
combustible wall with a minimum of 1
2˝/
305mm brick
separation from clay liner to combustibles. The
firecl
ay
liner shall run from outer surface of brick wall to, but not
beyond, the inner surface of chimney
flue
liner and shall
be fi
rmly cemented in place.
B. Insulated Sleeve
Solid-insulated, listed factory-built chimney length of the
same inside diameter as the chimney connector and
having
1˝/25.4cm
or more of insulation with a minimum
9˝/229mm
air space between the outer wall of the chim-
ney length and combustibles.
C. Ventilated Thimble
Sheet steel chimney connector, minimum
24
gauge in
thickness, with a ventilated thimble, minimum 2
4
gauge in
thickness, having two 1
˝/
25.
4
mm air channels, separated
from combustibles by a minimum of
6˝/152mm
of glass
fiber
insulation. Opening shall be covered, and thimble
supported with a sheet steel support, minimum 2
4
gauge
in thickness.
D. Chimney Section Pass-through
Solid insulated, listed factory-built chimney length with an
inside diameter 2
˝/
51mm larger than the chimney connec-
tor and having
1˝/25.4mm
or more of insulation, serving
as a pass-through for a single wall sheet steel chimney
connector of minimum
24
gauge thickness, with a mini-
mum
2˝/51mm
air space between the outer wall of chim-
ney section and combustibles. Minimum length of chim-
ney section shall be 12
˝/
305mm chimney section spaced
1˝/25.4mm
away from connector using sheet steel sup-
port plates on both ends of chimney section. Opening
shall be covered, and chimney section supported on both
sides with sheet steel support securely fastened to wall
surfaces of minimum 2
4
gauge thickness. Fasteners
used to secure chimney section shall not penetrate
chimne
y flue line
r.
NFPA 211 (US) NOTE: In Canada, installation must conform to CAN/CSA-B365 when passing through combustible
construction.
CHIMNEY CONNECTOR SYSTEMS & CLEARANCES
16
Summary of Contents for WS-TS-1500
Page 6: ...6 Minimum Clearances for installation according to UL 1482 US ULC S627 CAN A ...
Page 7: ...7 Top A A Alcove ...
Page 8: ...philips BLOWER ATTACHMENT 8 4 places A GASKET ...
Page 9: ...9 WS TS 2500 23 8 6 ...
Page 10: ...10 6 ...
Page 20: ...20 ...
Page 21: ...21 ...
Page 23: ...23 BAFFLE REMOVAL ...
Page 24: ...24 BAFFLE REMOVAL ...
Page 25: ...SERVICE PARTS 25 ...
Page 26: ...SERVICE PARTS 26 ...
Page 27: ...SERVICE PARTS 27 ...
Page 28: ...SERVICE PARTS 28 ...
Page 29: ...SERVICE PARTS 29 ...
Page 30: ...SERVICE PARTS WS TS 2500 30 ...
Page 33: ...DATE OF SERVICE PERFORMED BY DESCRIPTION CHIMNEY STOVE MAINTENANCE LOG 33 ...
Page 35: ...Warranty 35 ...
Page 36: ...36 www woodprostoves com 2 ...