background image

Operating instructions

GB

CONTROL PANEL

1.Power Key 

Press the ON/OFF button to start the machine. The 

machine’s default humidity is 50%,  Power indicator 

light is on. Press the ON/OFF key again to stop the 

machine. The related power indicator is off,  the fan 

continues to run for 15 seconds before shutting off.

2. Add humidity button 

Press this button increase set indoor humidity by 

1%, up to 95%. When the indoor humidity is lower 

than the set humidity, the unit will stop automati-

cally. When the indoor humidity is higher than set 

humidity the unit will automatically restart.

3. Minus Humidity button

 

Press this button to decrease set indoor humidity by 1%, down to 35%. When the indoor humidity lower than set 

humidity, the unit will stop working automatically. When the indoor humidity is higher than set humidity the unit 

will automatically restart

4. Continuous operation 

Press the Add and Minus key at the same time to activate continuous operation mode . The indication light

illuminates in green. In continuous mode the unit will defrost automatically and no values can be set manually. 

Press the Add and Minus key again to exit continuous working mode.

5.Manual drainage key (Optional: only on units equipped with a water pump)

Press this button to manually drain the water from the machine, for example before storage. The water pump 

will work for 15 seconds before shutting off.

INDICATION LIGHTS

Humidity display

This display window has two functions:

1. When the power is on, it shows indoor humidity

2. When you set humidity value, it shows the selected humidity

 

Power indicator light

When the power is connected, a buzzer is heard. Press the on/off button to start the unit. The power indicator 

light illuminates in red. 

Continuous working light

Press Add and Minus button at the same time to machine continuous operation mode. At this time, the light 

illuminates in green

Auto defrost

When the machine operates in low temperature, the dehumidifier will defrost automatically. The light 

illuminates in red.

        NOTE : 

      If the supply cord is damaged, it 

must be replaced by the manufacturer, 

its service agent or similarly qualified 

persons in order to avoid hazard.

Summary of Contents for DSC-70E

Page 1: ...DEHUMIDIFIER Users manual Wood s DSC 70E GB S Operating instructions Bruksanvisning Please read this manual carefully before installing and save the manual for future reference and product warranty...

Page 2: ...since mites and other creatures thrive in a damp environment A dehumid ifier with high performance creates a good healthy humidity level and for greatest efficiency the doors and windows of rooms tha...

Page 3: ...le or dangerous goods 4 Do not put fingers or other objects into air inlet or air outlet 5 Do not stand on the machine 6 Please drain water according to the instructions 7 Do not use this machine in a...

Page 4: ...lluminates in green In continuous mode the unit will defrost automatically and no values can be set manually Press the Add and Minus key again to exit continuous working mode 5 Manual drainage key Opt...

Page 5: ...be repaired before the unit can be used DRAINAGE PIPE CONNECTION The water pipe is 6 5 meters long and 10mm thick Connect one end of the pipe to the dehumidifier and lead the other end to a drain If t...

Page 6: ...dirty loosen in by rotating the frame Clean the frame in water Avoid using strong cleaners or solvents as this may damage the frame DEHUMIDIFIER STORAGE If the product isn t used for a long time pleas...

Page 7: ...ode E1 When LED shows E1 there is hu midity sensor trouble or humidity sensor connection wire isn t fixed Change the humidity sensor or check the connection wire Trouble code E2 When the LED shows E2...

Page 8: ...n s dan milj kan leda till sjukdomar hos dem som bor i huset d bl a kvalster trivs i en fuktig milj En avfuktare med h g prestanda skapar en bra och h l sosam fuktighetsniv och f r att n b sta effekt...

Page 9: ...grar eller andra objekt i luftutbl set eller luftintaget 5 St inte p maskinen 6 F lj instruktionerna f r vattenavledningen 7 Anv nd inte maskinen i tillslutna rum 8 Om avfuktaren inte har n gon pump b...

Page 10: ...Lampan lyser gr nt och avfuktaren kommer att arbeta kontinuerligt tills den st ngs av I kontinuerligt l ge avfrostar maskinen automatiskt och du kan inte st lla in nskad luftfuktighet Tryck p pil upp...

Page 11: ...2 och avfuktaren kan inte anv ndas f rr n problemet r tg rdat SLANGANSLUTNING Slangen r 6 5 m l ng och 10 mm tjock Anslut slangen till avfuktaren och f r den andra nden till ett avlopp Av loppet kan i...

Page 12: ...smutsigt lossa den genom att f rsiktigt vrida p ramen Reng r ramen med vatten Undvik att anv nda l sningsmedel eller starka reng ringsmedel d det kan skada ramen F RVARING Om du inte kommer anv nda a...

Page 13: ...eller s r den inte korrekt inkopplad Byt ut fuktighetssensorn eller kon trollera att den r korrekt inkop plad Felkod E2 N r displayen visar E2 r det prob lem med vattenpumpen Byt ut eller reparera vat...

Page 14: ...Contact Wood s is marketed and distributed by TES Scandinavia AB Kroksl tts fabriker 30 431 37 M lndal Sweden 46 0 31 761 36 10 www woodseurope com info woods se...

Reviews: