background image

04

EN

INSTRUCTIONS FOR USE

INSTRUCTIONS FOR USE”

”Flammable material. This appliance 

contains R290/Propane a flammable 

refrigerant.

   

Refer operators manual.

   Read technical manual

    

Read operators manual.

SAFETY INFORMATION

Before the installation and use of the 

appliance, carefully read the supplied 

instructions. The manufacturer is not 

responsible if an incorrect installation and 

use causes injuries and damages. Always 

keep the instructions with the appliance 

for future reference.

CHILDREN AND VULNERABLE PEOPLE 

SAFETY

WARNING 

  

Risk of injury or permanent disability. 

This appliance can be used by children 

aged 8 years and above and persons 

with reduced physical, sensory or mental 

capabilities or lack of experience and 

knowledge if they have been given 

supervision or instruction concerning 

use of the appliance in a safe way and 

understand the hazards involved. Do not 

let children play with the appliance.

Children of less than 3 years should be 

kept away unless continuously supervised.

Keep all packaging away from children. 

Cleaning and user maintenance shall not 

be made by children without supervision.

GENERAL SAFETY

This appliance is intended to be used in 

household and similar applications such 

as: – basements, crawl spaces; staff kitchen 

areas in shops, offices and other working 

environments. The rating plate is located 

behind the water tank of the dehumidifier. 

Keep ventilation openings clear of 

obstruction.

Do not use mechanical devices or other 

means to accelerate the defrosting 

process, other than those recommended 

by the manufacturer. The appliance shall 

not be stored in a room where ignition 

sources are operating continously (open 

flames, working gas appliance, operation 

electric heater, etc). Do not pierce or burn. 

Be aware that refrigerants may not have an 

odour. Do not use water spray and steam 

to clean the appliance. Clean the appliance 

with a moist soft cloth. Only use neutral 

detergents. Do not use abrasive products, 

abrasive cleaning pads, solvents or metal 

objects. If the power cord is damaged, it 

must be replaced by the manufacturer, 

its authorized Service Centre or similarly 

qualified persons in order to avoid a 

hazard.

SAFETY INSTRUCTIONS

WARNING 

  

Only a qualified person can install this 
appliance. 

Remove all packaging material. Do not 

install or use a damaged appliance. The 

appliance shall be installed, operated and 

stored in a room with a floor area larger 

than 4m². Strictly follow the installation 

instruction supplied with the appliance. 

Always be careful when you move the 

appliance because it is heavy. Always wear 

safety gloves.

Make sure the air can circulate around 

the appliance. Wait at least 4 hours before 

connecting the appliance to the power 

outlet. This is to allow the oil to flow back 

in the compressor. Do not install the 

appliance close to radiators or other heat 

sources. Do not install the appliance in 

direct sunlight.

ELECTRICAL CONNECTION

WARNING 

  

Risk of fire and electrical shock. 

The appliance must be connected to 

a grounded outlet. Make sure that the 

electrical information on the rating label 

is in accordance to the power supply. If 

not, contact an electrician. Always use a 

correctly installed shockproof socket. Do 

not use multi-plug adapters and extension 

cables. Make sure not to cause damage 

to the electrical components (e.g. plug, 

cable). ontact the authorized Service 

Centre or an electrician to change the 

electrical components. The cable must stay 

below the level of the plug. Connect the 

plug to the power socket only at the end 

of the installation. Make sure that there is 

access to the plug after the installation. Do 

not pull the power cable to disconnect the 

appliance. Always unplug the power cable 

from the plug only.

USE

WARNING 

  

Risk of injury, burns, electrical shock or fire. 

Do not change the specification of this 

appliance. Be careful not to cause damage 

to the refrigerant circuit. It contains 

propane (R290), a natural gas with a high 

level of environmental compatibility. This 

gas is flammable. If damage occurs to the 

refrigerant circuit, make sure that there 

are no flames and sources of ignition in 

the room. Ventilate the room. Do not put 

flammable products or items that are wet 

with flammable products near or on the 

appliance.

DISPOSAL

WARNING 

  

Risk of injury. 

Disconnect the appliance from the mains 

supply. Cut off the mains cable and 

discard it. The refrigerant circuit of this 

appliance is ozone-friendly. Contact your 

local authority for information on how to 

discard the appliance correctly. Do not 

cause damage to the part of the cooling 

unit that is near the heat exchanger.”

Summary of Contents for LD24

Page 1: ...LD40PRO LD24 EN Instructions for use SV Bruksanvisning DEHUMIDIFIER Revision date 01 Jun 2021 Wood s LD48 LD44 LD40 OPERATING INSTRUCTIONS FOR DEHUMIDIFIER OPERATING INSTRUCTIONS FOR SW45FB...

Page 2: ...USE GET 10 YEARS WARRANTY Register and follow the instructions at warranty woods com Registrera dig och hitta den senast uppdaterade bruksanvisningen p woods se Register and find the latest uppdated u...

Page 3: ...03 EN INSTRUCTIONS FOR USE English 04 Swedish 12 CONTENT PAGE NO...

Page 4: ...G Only a qualified person can install this appliance Remove all packaging material Do not install or use a damaged appliance The appliance shall be installed operated and stored in a room with a floor...

Page 5: ...ME LOCAL NAME SHEET DESCRIPTION XXX XXX 1 1 1 5 DRAWING NUMBER REV B 0 5 C A DO NOT MEASURE OFF DRAWING FOR MISSING DIMENSIONS REFER TO 3D MODEL GENERAL TOLERANCES UNLESS STATED OTHERWISE SHEET METAL...

Page 6: ...06 EN INSTRUCTIONS FOR USE PRODUCT DESCRIPTION A 1 1 Hygrostat dial 2 2 Controls for closing opening aiming the return air 3 3 Air filter 4 4 Water tank 5 5 Replacing the air filter...

Page 7: ...humidifier does not start Make sure the fan wheel is spinning Make sure that the air can flow freely through the dehumidifier Air emissions and air filters must be clean and the dehumidifier must be a...

Page 8: ...e dehumidifier should be placed at least 25 cm away from walls and other obstruction to ensure maximum air flow It is ideal to place the dehumidifier as centrally in the room area as possible 1 Check...

Page 9: ...E Unplug the power cord from the electrical outlet before cleaning HINTS For maximum dehumidification capacity in a room it is recommended that the supply air from the outside and adjoining rooms are...

Page 10: ...t least once a year If you want we ll send you a reminder when a filter change is due The reminder is of course free of charge You can find filters at your local retailer or distributor Please visit w...

Page 11: ...11 EN INSTRUCTIONS FOR USE...

Page 12: ...r f r att undvika fara S KERHETSF RESKRIFTER VARNING Denna apparat f r endast installeras av en fackman Ta bort allt emballage Installera inte eller anv nd apparaten om den r skadad Apparaten ska inst...

Page 13: ...LOCAL NAME SHEET DESCRIPTION XXX XXX 1 1 1 5 DRAWING NUMBER REV B 0 5 C A DO NOT MEASURE OFF DRAWING FOR MISSING DIMENSIONS REFER TO 3D MODEL GENERAL TOLERANCES UNLESS STATED OTHERWISE SHEET METAL COM...

Page 14: ...14 SV BRUKSANVISNING PRODUKTBESKRIVNING A 1 Hygrostatvred 2 Reglage f r att st nga ppna rikta returluften 3 Luftfilter 4 Vattenbeh llare 5 Byte av luftfilter...

Page 15: ...ll max Avfuktaren ska d starta inom 5 min Enheten avfuktar inte Se till att fl kten snurrar Se till att luften kan fl da fritt genom avfuktaren Luftutsl pp och luftfilter ska vara rena och avfuktaren...

Page 16: ...ement eller v rmefl kt f r att h lla temperaturen ovan 2 C Avfuktaren ska st minst 25 cm fr n v ggen och andra hinder f r att luftgenomstr mningen ska vara maximal Det r idealiskt att placera avfuktar...

Page 17: ...NAME LOCAL NAME SHEET DESCRIPTION XXX XXX 1 1 1 5 DRAWING NUMBER REV OBS Koppla bort n tsladden fr n eluttaget innan reng ring TIPS F r maximal avfuktningskapacitet i ett rum rekommenderas att tilluft...

Page 18: ...p minnelse p SMS och eller e mail n r det r dags att byta filter Detta v ljer du vid registreringen p warranty woods com P minnelsen r givetvis kostnadsfri Nya Wood s filter k per du hos din lokala t...

Page 19: ......

Page 20: ...d by Woods TES Sweden AB Maskingatan 2 4 441 27 Alings s Sweden woods se info woods se 46 317613610 Wood s is marketed and distributed by Woods Production AB Maskingatan 2 4 441 27 Alings s Sweden woo...

Reviews: