07
EN
INSTRUCTIONS FOR USE
TECHNICAL DATA
LD24
LD40PRO
Max working area
80 m
2
180 m
2
Air flow step 1
200 m
3
/h
300 m
3
/h
Dehumidifying at 20˚C and 70% r.h.
6,5 L/24h
16 L/24h
Dehumidifying at 30˚C and 80% r.h.
12 L/24h
31 L/24h
Power at 20˚C and 70% r.h.
160 W
450 W
Energy consumption at 20˚C och 70% r.h.
4,3 kWh/24 h
9,1 kWh/24 h
Tank volume
11,4 liters
11,4 liters
Refrigerant
R290
R290
Refrigerant change
99 g
130 g
Voltage
230 V
230 V
Frequency
50 Hz
50 Hz
Fuse
10 A
10 A
IP-class
X1
X1
Dimensions (L x W x H)
400 x 345 x 580 mm
400 x 345 x 580 mm
*Technical changes and improvements may occur. All values are approximate and may vary depending on external circumstances such as
temperature, ventilation and humidity.
PROBLEM
REMEDY
The dehumidifier does not start
• Make sure that the dehumidifier is connected to the socket and that the fuse has not blown.
• If the indicator light is red, check that the water tank is empty and correctly positioned in the dehumidifier. Ensure the
float hangs freely.
• Check that the hygrostat works by turning it up to max. The dehumidifier should then start within 5 min.
The dehumidifier does not start
• Make sure the fan wheel is spinning.
• Make sure that the air can flow freely through the dehumidifier. Air emissions and air filters must be clean and the
dehumidifier must be at least 20-30 cm from the wall.
• Listen if the compressor is running, but keep in mind that the dehumidifier may be defrosting cycle and then the
compressor will stop. Start by waiting for about 30 minutes.
• Check that a thick layer of ice does not form on the cooling coils / slats behind the filter.
High noise level/rattling
• Increase the distance between the dehumidifier and surrounding surfaces.
• The cooling coils may make contact to each other and cause vibrations. Disconnect the dehumidifier from the electrical
outlet and separate the loops
No condensate water collected
• Check that no dirt etc. is deposited on the drip tray underneath the cooling coils, clean if necessary.
• Check that the temperature is above 2 ° C or below 35 ° C.
Does not shut off when water tank is full.
• It is important that the float hangs freely in the water tank. If it does not, it does not sense the water level is and can
therefore not ensure that the dehumidifier stops
If you have a problem with your dehumidifier, refer the troubleshooting guide. If none of the above works, contact your dealer to get your
dehumidifier serviced.
Summary of Contents for LD24
Page 3: ...03 EN INSTRUCTIONS FOR USE English 04 Swedish 12 CONTENT PAGE NO...
Page 11: ...11 EN INSTRUCTIONS FOR USE...
Page 19: ......