01
Technical drawings
Operating instructions
02
03 -04
CONTENTS:
PAGE NO.
GENERAL WARNINGS AND GUIDELINES:
•
T
his appliance should not be used by children aged from 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of experience and knowledge without supervision or
instructions concerning the use of the appliance and the hazards involved.
•
Children shall not play with the appliance. Cleaning and user maintenance shall not be made by
children without supervision.
•
E
nsure there is 30 cm of clear space on all sides of the unit.
•
T
he character of fuse to replace the one on PCB shall be AC250V; T; 10A; L.
•
T
he appliance must be installed in accordance with national wiring regulations.
•
This appliance is for indoor use only
.
•
B
efore any maintenance or cleaning, please switch off and unplug the unit.
This marking indicates that this product should not be disposed with other household
wastes throughout the EU. To prevent possible harm to the environment or human
health from uncontrolled waste disposal, recycle it responsibly to promote the sustain-
able reuse of material resources. To return your us device, please use the return and
collection systems or contact the retailer where the product was purchased. They can
take this product for environmental safe recycling.
Operating instructions
GB
TROUBLE SHOOTING
- Check for obstruction to drip-tray above water reservoir
Does not turn off when
- It is important that the float moves freely in the water reservoir. If it does not, it will not
water reservoir is full
respond to water levels and prevent dehumidifier from stopping
- Remove air filter at rear of dehumidifier and check that no dust or fluff is obstructing
passage of air through machine
- Timer which controls defrosting may be broken, in which case compression will not stop
regularly
- Increase distance between dehumidifier and surrounding surfaces
- Check that the unit is connected to electricity and that fuse has not gone
- If the warning light is on, check that the water reservoir is empty and correctly placed in
the dehumidifier.
- Check that float is free
- Check that fan is spinning
- Check that air can flow freely through the dehumidifier. Front grid and air filter should be
clean and dehumidifier should stand 20-30 cm from wall
- Listen for sound of compression, but bear in mind that the dehumidifier may be in a
dehumidifying cycle, when the compression stops. Wait initially for about 35 minutes.
- Check that a thick coating of ice has not formed on the cooling coils
SOLUTION
PROBLEM
Dehumidifier doesn’t start
Does not dehumidify
High noise level
Ice formation on cooling coils
No water enters reservoir
If none of the above works, you should contact your nearest retailer for checking and possible overhaul of dehumidifier
05
02
05
Using your dehumidifier