Initial Start-up & Operation

Initial Start-up 

Operation

Operation

Upon setting up your equipment, refer to these instructions to adjust the thermostat control settings:

Power ON/OFF

Temperature Adjustment

To start a manual defrost�

To see the max stored temperature; in programming mode it browses the parameter codes or increases
the displayed value�
To see the min stored temperature; in programming mode it browses the parameter codes or increases
the displayed value�

To switch the instrument off, if onF = oFF�

Not Enabled�

(DEF)

KEY FUNCTIONS:

(UP)

(DOWN)

To lock and unlock the keyboard�

To enter in programming mode�

To return to the room temperature display�

KEY 

COMBINA

TIONS:

1� Push and immediately release the 

SET

 key, the display will show the Set point value;

2� Push and immediately release the 

SET

 key or wait 5 seconds to display the probe value again�

HOW TO SEE THE SET POINT:

1� Push the 

SET

 key for more than 2 seconds to change the Set point value;

2� The value of the set point will be displayed and the “˚C” or “˚F” LED starts blinking;

4� To memorise the new set point value push the 

SET

 key again or wait 10 seconds�

HOW TO CHANGE THE SET POINT:

3� To change the set point value push the      or      arrows within 10 seconds�

Summary of Contents for W.CFC23

Page 1: ...ality Woodson product Specification Installation and Operation Manual Models W CFS23 W CFS24 W CFS25 W CFS26 W CFC23 W CFC24 W CFC25 W CFC26 Cold Food Displays Rev A 26 02 2018 Phone 0800 503 335 Spar...

Page 2: ...Page Intentionally Left Blank...

Page 3: ...7 Information Specification Climate Classes 8 Information Technical Specifications 8 W CFS23 W CFS24 W CFS25 W CFS26 W CFC23 W CFC24 W CFC25 W CFC26 Operation Initial Start up Operation 13 Initial Sta...

Page 4: ...of reliable service Stoddart is a wholly Australian owned company which manufactures and distributes Woodson commercial catering equipment Stoddart products are manufactured and or engineered in Austr...

Page 5: ...t of pinch point areas Unit is not waterproof DO NOT use jet sprays hoses or pour water over on the exterior of the unit Only use this unit with voltage specified on the rating label Do NOT remove any...

Page 6: ...upporting its weight Do not position the unit in a wet area an area with a lot of heat and steam or near ammable substances Allow an air gap between the unit and other objects or surfaces We recommend...

Page 7: ...the lines when leaving the factory should be 1380kPa 200psi Contact the manufacturer to confirm Any pressure loss MUST be reported to the distributor or manufacturer and fixed before the unit is used...

Page 8: ...pressed in kilowatts in this manual Single Phase Units Supplied with an appropriately rated plug and lead fitted and be indicated as 10A plug lead fitted 15A plug lead fitted 20A plug lead fitted Some...

Page 9: ...h an M1 class package would be designated as 3M1 Refrigerated Units in Commercial Kitchens would normally be climate class 4 CLIMATE CLASSES Test Room Climate Class Dry bulb temperature C Relative hum...

Page 10: ...Page 9 Specification W CFS24 210 528 36 310 404 547 404 1355 1355 690 382 W CFS23 1030 1030 690 382 210 241 241 547 528 36 310...

Page 11: ...Page 10 W CFS25 W CFS26 Specification 210 528 36 310 1680 1680 566 566 547 690 382 210 528 36 310 2005 729 729 547 690 382 2005...

Page 12: ...Page 11 Specification W CFC23 W CFC24 1030 547 241 241 481 691 600 272 R 2 0 0 7 0 528 36 36 382 30 210 272 R 2 0 0 528 36 382 30 210 481 1355 547 404 404 691...

Page 13: ...Page 12 Specification W CFC26 W CFC25 272 R 2 0 0 528 36 382 30 210 481 547 566 566 691 1680 272 R 2 0 0 528 36 382 210 481 547 729 729 691 2005...

Page 14: ...onF oFF Not Enabled DEF KEY FUNCTIONS UP DOWN To lock and unlock the keyboard To enter in programming mode To return to the room temperature display KEY COMBINATIONS 1 Push and immediately release th...

Page 15: ...left in the unit This unit is NOT designed to store product after hours The unit MUST be switched OFF If the unit is moved for night storage ensure the castors are locked mobile units only Food Storag...

Page 16: ...n can be treated with a commercial cleaning agent that contains citric oxalic nitric phosphoric Do NOT use cleaning agents with chlorides or other harsh chemicals as this can cause corrosion After tre...

Page 17: ...pool on the unit Check crevices and folds Note In some areas particularly seaside environments stainless steel can be subject to surface discolouration or tea staining This can be removed with an appr...

Page 18: ...controller Continuous cycle setting ON integral units Turn ON condenser unit Turn the main switch ON Replace Fix electrical wiring Replace Fix refrigeration unit Replace controller Move away from air...

Page 19: ...Page 18 Notes...

Reviews: