16. Troubleshooting
The table below contains a list of error symptoms and explains what you can do to solve the problem if your tool fails to
work properly. If the problem persists after working through the list, please contact your nearest service workshop.
Malfunction
Possible cause
Remedy
The hydraulic pump does not
start
No electric power
Check cable for electric power
Thermal switch of motor cut off
Engage thermal switch inside the motor casing
again
The column does not move
down
Low oil level
Check oil level and refill
One of the levers not connected
Check fixing of lever
Dirt in the rails
Clean the column
Motor starts but column does
not move down
Wrong turning direction of 3-phase
motor
Check turning direction of motor and change