Grounding Requirements
Extension Cords
This machine MUST be grounded. In the event of certain
types of malfunctions or breakdowns, grounding provides
a path of least resistance for electric current to travel—in
order to reduce the risk of electric shock.
Improper connection of the equipment-grounding wire will
increase the risk of electric shock. The wire with green
insulation (with/without yellow stripes) is the equipment-
grounding wire. If repair or replacement of the power
cord or plug is necessary, do not connect the equipment-
grounding wire to a live (current carrying) terminal.
Check with a qualified electrician or service personnel
if you do not understand these grounding requirements,
or if you are in doubt about whether the tool is
properly grounded. If you ever notice that a cord or
plug is damaged or worn, disconnect it from power, and
immediately replace it with a new one.
For 220V Connection
We do not recommend using an extension cord with
this machine. Extension cords cause voltage drop, which
may damage electrical components and shorten motor
life. Voltage drop increases with longer extension cords
and smaller gauge sizes (higher gauge numbers indicate
smaller sizes).
Any extension cord used with this machine must contain a
ground wire, match the required plug and receptacle, and
meet the following requirements:
Grounding Pin
Current Carrying Prongs
6-15 PLUG
GROUNDED
6-15 RECEPTACLE
220V
Figure
6
.
NEMA 6-15 plug & receptacle.
DO NOT modify the provided plug or use
an adapter if the plug will not fit your
receptacle. Instead, have a qualified
electrician install the proper receptacle
on a power supply circuit that meets the
requirements for this machine.
Minimum Gauge Size at 220V ...................... 14 AWG
Maximum Length (Shorter is Better) ................50 ft.
The power cord and plug specified under "Circuit
Requirements for 220V" on the previous page has an
equipment-grounding wire and a grounding prong. The
plug must only be inserted into a matching receptacle
(outlet) that is properly installed and grounded in
accordance with all local codes and ordinances (see figure
to the right).