Manual 02880
723PLUS/Single Engine Marine Propulsion
Woodward
27
2.
Check for grounds
Check for grounds by measuring the resistance from all control terminals to
chassis. All terminals should measure infinite resistance (the resistance of
terminals 2 and 37 depends on whether a floating or grounded power
source is used). If a resistance less than infinity is obtained, remove the
connections from each terminal one at a time until the resistance is infinite.
Check the line that was removed last to locate the fault.
Summary of Contents for 723PLUS
Page 8: ...723PLUS Single Engine Marine Propulsion Manual 02880 vi Woodward ...
Page 15: ...Manual 02880 723PLUS Single Engine Marine Propulsion Woodward 7 ...
Page 17: ...Manual 02880 723PLUS Single Engine Marine Propulsion Woodward 9 ...