723PLUS/Single Engine Marine Propulsion
Manual 02880
80
Woodward
Conclusion of Initial Adjustment Procedures
This completes the initial adjustments. Save the set points by pressing the
“SAVE” key on the Hand Held Programmer or save settings using the 723PLUS
Marine SEP Control View interface or Watch Window (refer to “help” if you need
help). Run through all the set points and record them in the Appendix for future
reference. Settings can also be saved to a file using the 723PLUS Marine SEP
Control View interface or Watch Window for later download. This can be very
useful if a replacement control is necessary or for start-up of another similar unit.
Power down the control for about 10 seconds. Restore power and verify that all
set points are as recorded.
To prevent possible damage to the engine resulting from improper
control settings, make sure you save the set points before removing
power from the control. Failure to save the set points before
removing power from the control causes them to revert to the
previously saved settings.
Disconnect the Hand Held Programmer from the control (if applicable). The
723PLUS Marine SEP Control View interface or Watch Window may remain
connected or removed from the control at the end user’s discretion. Close the
cover over J1 and re-tighten the retaining screw if connection is removed.
Summary of Contents for 723PLUS
Page 8: ...723PLUS Single Engine Marine Propulsion Manual 02880 vi Woodward ...
Page 15: ...Manual 02880 723PLUS Single Engine Marine Propulsion Woodward 7 ...
Page 17: ...Manual 02880 723PLUS Single Engine Marine Propulsion Woodward 9 ...
Page 116: ...723PLUS Single Engine Marine Propulsion Manual 02880 108 Woodward ...