AtlasPC Digital Control, Vol. I
Woodward
3
Control Accessories
The AtlasPC digital control platform is designed to interface with several
Woodward service tools and commercial software products. Available tools are
listed below with a brief description of their functionality:
•
Watch Window
—Provides an Ethernet or serial connection to the control to
allow 1) initial configuration of the unit; 2) monitoring and tuning of system
variables; and 3) management of configuration and setpoints.
•
Control Assistant
—Ethernet connection to the control for viewing of high-
speed data captures and other useful utilities.
•
Application Manager
—Ethernet access to the control for program loading,
network configuration and support, and system diagnostics.
•
HMI (Human Machine Interface)
—Commercially available HMI programs
interface to the AtlasPC control through Ethernet or serial connections to
provide operator access and control of the application machinery.
Regulatory Compliance
The AtlasPC™ control is suitable for use in Class I, Division 2, Groups A, B, C,
D, per UL for Canada and US or non-hazardous locations only.
The AtlasPC control is suitable for use in European Zone 2, Group IIC
environments when installed in an IP-54 minimum rated enclosure per DEMKO
certification.
Wiring must be in accordance with North American Class I, Division 2 or
European Zone 2 wiring methods as applicable, and in accordance with the
authority having jurisdiction.
Field wiring must be suitable for at least 75 °C for operating ambient
temperatures expected to exceed 50 °C.
A fixed wiring installation is required.
Do not connect more than one main power supply to any one fuse or circuit
breaker.
Connect ground screw to earth ground (see Figure 1-2).
These listings are limited to those units bearing the UL or DEMKO agency
identifications.
EXPLOSION HAZARD—Do not connect or disconnect while circuit is
live unless area is known to be non-hazardous.
Substitution of components may impair suitability for Class I,
Division 2 or Zone 2 applications.
Ne pas raccorder ni débrancher tant que l’installation est
sous tension, sauf en cas l’ambiance est décidément non
dangereuse.
La substitution de composants peut rendre ce matériel
inacceptable pour les emplacements de Classe I, Division 2
ou Zone 2.