Products:  

Genset Controllers 

Device Series:  easYgen-3000XT 
Devices: 

easYgen-3100XT/3200XT/3400XT/3500XT 

37630 easYgen-3000XT Flash Instruction 

 

w w w . w o o d w a r d . c o m 

EASYGEN-3000XT FLASH INSTRUCTION        #37630 

 

Flashing a Woodward easYgen-3000XT device for full or partial update

 

 

 

For trained personnel only! 
Updating the device software needs expert level. Otherwise, the device 
can become unusable or even cause error function that can lead into 
dangerous situation with genset. 

 

DO NOT switch off the device  
until the flash procedure is explicitly mentioned as  
completely finished as described below 

 

If the device to be updated is installed into a running genset system, it 
is mandatory that a genset control expert guarantees trouble free 
system setup during update process. 

 

 

If firmware update process is however interrupted before it has finished, 
due to lost or switched off power supply, your device may be no longer 
able to operate. 
Note that you perform firmware update at your own risk. 

 
 

What to do? 

The updating process comes with conditions, which need certain preparations, ask for step-by-step procedure, 
and will be closed with some final preparations. 
First, read this instruction manual completely and carefully, before you start updating your device. 
 

 

 

Released

Summary of Contents for EGCP-2 to easYgen-3200XT

Page 1: ...e is explicitly mentioned as completely finished as described below If the device to be updated is installed into a running genset system it is mandatory that a genset control expert guarantees troubl...

Page 2: ...ommunicating to other devices PC or laptop computer connected to the device via the preferred interface type and cable Current version of update file scp according to the actual device and the preferr...

Page 3: ...as wset file on your computer to ensure re storing it later 1 Start ToolKit software 2 Open the appropriate configuration file wtool which fits to your device 3 Click the Connect icon Connection sele...

Page 4: ...2 Continue with Next Application File Selection window opens 3 Click Browse and select the provided scp file If available select _eth scp or _usb scp with respect to the appropriate interface to whic...

Page 5: ...apter Preparations step 4 and login with code for Code Level 5 If Production Identifier Mismatch window appears The scp file you have selected does not fit to the hardware of that device Click Cancel...

Page 6: ...lete and the display is showing home screen Check the firmware version how to check the firmware version is described below b Back panel variant Observe the LEDs When you observe the LEDs have become...

Page 7: ...itch off the device After about 30 seconds the LEDs will start blinking in turn for about 2 30 minutes Afterwards both LEDs again turn red for a moment DO NOT switch off the device 8 After the device...

Page 8: ...Language must have the same version If there is any discrepancy there will show an exclamation mark besides the respective version HMI Screen ToolKit screen HMI screen In this case please contact your...

Page 9: ...r your latest specific settings are still again loaded If not Re load your latest saved settings or execute factory settings Undo temporary safety preparations Re connect all interface connections tha...

Page 10: ...TIES OF ANY KIND EXPRESSED OR IMPLIED THE ADHERENCE TO THE INFORMATION CONTAINED IN THIS APPLICATION NOTE SHALL BE AT THE USER S OWN RISK WOODWARD EXPRESSLY DISCLAIMS ANY REPRESENTATIONS OR WARRANTIES...