background image

Thank you for purchasing the dual purpose RC400 Wired Digital Door Key / Digital Touch Pad.

1

 

COMPOSITION & SPECIFICATIONS

Wired Digital Door Key (RC400)

Mounting screws (4x16)

Mounting template

Connection wire

1EA

2EA

1EA

1EA

User’s Manual

1 copy

Power supply

Relay contact capacity

Operating temperature

Type

Power consumption

International Protection

DC 12~30V,  AC 12~24V

DC30V / 1A

-20

~50

ISO14443A(Mifare)  / 13.56MHz

300mA Under

IP54 (water proof)

Composition

Specification

D

igital

Wired Door Key 

(RC400)

User Guide

2

 DIMENSION

Unit : mm

3

 

OPERATION CHECK & CAUTION

5

 

CONTACT TIME

HOW TO USE  

1. Be sure to connect DC12 ~ 30V / AC12 ~ 24V.

2. When it powers on, the LEDs will be displayed sequentially: once all LEDs have been displayed, “beep” sound is heard.

3. Since this system is capacitive touch type, it will not respond to a gloved hand.

①②③④ ⇒ ①②③④ ⇒ # ⇒ ① ⇒ # ⇒ Access card (Serial registration is possible) ⇒ # ⇒ * (end)
①②③④ ⇒ ①②③④ ⇒ # ⇒ ① ⇒ # ⇒ Card address(0001~0500) ⇒ Card ⇒ # ⇒ * (end)
Example) Serial registration : if the first address is [0100], next address is [0101] automatically increase.

①②③④ ⇒ ①②③④ ⇒ # ⇒ ③ ⇒ # ⇒ Card address (4digit or serial delete) ⇒ # ⇒ * (end)

4)

   

[Contact Time]

①②③④ ⇒ ①②③④ ⇒ # ⇒ ⑤ ⇒ # ⇒ 01~60 (01~60sec.) ⇒ # ⇒ * (end)
Example) Setup 2sec : 0+2, 20sec : 2+0 (Default value: 2sec)

5)

   

[All Card Delete]

①②③④ ⇒ ①②③④ ⇒ # ⇒ ⑥ ⇒ # (end)

6)

  

 [All Password Delete]

①②③④ ⇒ ①②③④ ⇒ # ⇒ ⑦ ⇒ # (end)

7)

   

[Card or Password Delete] 

Card : ①②③④ ⇒ ①②③④ ⇒ # ⇒ ⑧ ⇒ # ⇒ Access Card (Serial possible) ⇒ # ⇒ * (end)
Password : ①②③④ ⇒ ①②③④ ⇒ # ⇒ ⑧ ⇒ # ⇒ Password ⇒ # ⇒ * (end)

8)

   

[Toggle mode contact change]

①②③④ ⇒ ①②③④ ⇒ # ⇒ ②ⓞ ⇒ # ⇒ Set value (ⓞ~①) ⇒ # (end)
Set value - ⓞ : Normal , ① : Toggle mode (Default value : ⓞ)

9)

   

[Operation mode setting]

①②③④ ⇒ ①②③④ ⇒ # ⇒ ⑨ ⇒ # ⇒ Set value (ⓞ~①) ⇒ # ⇒ * (end) 
Set value - ⓞ:NO, ①: NC (Default value : ⓞ)

10)

   

[Touch switch mode setting]

①②③④ ⇒ ①②③④ ⇒ # ⇒ ①① ⇒ # ⇒ Set value (ⓞ~①) ⇒ #  (end)

Set value - ⓞ: touch switch mode is activated, ①: touch switch mode is deactivated (Default value : ⓞ )

  For more detailed information, please refer to the back page “setting touch function to active”

11)

   

[Illumination brightness setting]  

①②③④ ⇒ ①②③④ ⇒ # ⇒ ①② ⇒ # ⇒ Set value ⓞ~⑨) ⇒ # ⇒ * (end)

Set value -ⓞ: Illumination OFF, ⑨: The highest degree of brightness (Default value :  ② )

In case brightness of the illumnination is set at off, press touch pad then the numbers will be appeared.

12)

   

[System number change]

①②③④ ⇒ ①②③④ ⇒ # ⇒ * ⇒ # ⇒ # ⇒ Number in use ⇒ # ⇒ New Number ⇒ # (end)
System number must be 4 digits (Default value : 1234)

13)

   

[System Initialization] 

①②③④ ⇒ ①②③④ ⇒ * ⇒ # ⇒ Initializing ⇒ Exit after the LEDs blink. ⇒ (end)

①②③④ ⇒ ①②③④ ⇒ # ⇒ ② ⇒ # ⇒ Password(4digit) ⇒ # ⇒ * (end)
                                                                                                   

(Serial registration)

Power 

(DC 12~30V,  AC 12~24V)

Yellow
Yellow
White
White
Gray
Gray

External Input

Output Contact

2)

   

[Password Registration]

3)

   

[Card address Delete]

1)

   

[Card Registration]

6

 

EM LOCK WIRING

Output Contact

EM Lock

Adapter

Wiring

Wired Digital

Door Key

20

41

150

3

 

GENERAL INFORMATION

Unfasten the screw, 
and use a flat blade (

)screwdriver 

to disassemble it, 
as shown in the figure below.

Water proof pad (Silicone rubber)
Between outside gaps

Screw for 
disassembling
/assembling

Lower case

Connection 
wire hole

Mounting screws

Disassembling the upper case

Water proof pad (Silicone rubber)

(When assembling the product,
the water proof pad should
not be twisted)

: Error

: Touch

: Ac on / Set

Upper case

Button 

 Use after removing the protective film

*  

Reviews: