35
Is there a 230V AC live
supply across
Terminal
ST2
pins
L
and
N
?
Switch off electrical
power.
Has fuse
F1
blown?
Caused by mains 230V
parts external to the
control board ie (wiring
to or faults within)
pump, fan, transformer
or other external
controls connected to
ST2. Check all these
parts for malfunction.
Repair/replace part,
replace fuse and run
boiler.
Note:
tracks on board
may also be damaged.
Replace board if
necessary
Check electrical
supply to boiler.
Has fuse
F2
blown?
TEST A
No
Yes
Yes
No
Likely to be caused by
control board internal
fault or low voltage
wiring (eg shorts to
chassis). Replace fuse
F2 and check wiring
or replace control
board.
Remove control board from facia
and separate transformer from
board. Measure resistance across
the two pairs of adjacent pins on
the transformer. Is any coil above
120 ohms?
Replace transformer.
Yes
Yes
No
Replace
control
board.
No
NOTE: It is normal for
there to be no facia
lights if the boiler is in
normal overtempera-
ture condition.
Continue this test if
this fault occurs when
the appliance is cold.
Is there a 230V AC live
supply across
Terminal
ST2
pins
Lr
and
N
?
TEST B
No
Yes
Yes
Replace
control
board.
NOTE: Lights will be
off and pump will run
if boiler is in 3min
anticycle condition.
With CH control knob
fully clockwise, if
there is still no CH
function, continue:
There is no heat
demand. Check room
thermostat or external
programmer (or link).
Is there a facia
mounted programmer
at connection
ST5
at
right-hand end of
board?
No
No
Remove programmer
connector from edge
of board. Does the
boiler now ignite?
Correctly set or
replace programmer.
Yes