Switch on the gas and electricity supplies. Check for gas
tightness at the gas valve inlet.
Refer to Section12-Commissioning for the method of checking
the pressures.
Check for gas soundness at the gas valve outlet.
Adjust the maximum and start pressure [minimum], as
necessary, to obtain the required pressures.
Switch off the appliance and disconnect the pressure gauge.
15.4.2
Spark Electrode
Remove the inner casing and the combustion chamber.
Carefully pull off the leads from the electrodes. Loosen the screw
and remove the spark electrode assembly. Refer to Fig 46.
15.4.3
Flame Sense Electrode
Remove the inner casing and the combustion chamber.
Carefully pull off the lead from the electrode. Loosen the screw
and remove the flame sensing electrode assembly. Refer to Fig
47. Ensure that the electrode is at the correct height above the
burner blade.
15.4.4
Burner
Remove the inner casing and the combustion chamber.
Remove the electrode connections.
Release the union connection beneath the burner and remove
the burner from the appliance. Refer to Fig 44.
Do not omit the gasket when fitting the new burner.
15.4.5
Combustion Chamber Insulation
Remove the burner as described in 15.3.4 preceding.
Remove the primary heat exchanger as described in 15.4.21
following.
Replace the side and front pads in the combustion chamber
assembly. Refer to Fig 48.
Replace the rear insulation pad.
23
Fig.45 . Lower casing - gas and water
controls.
1
Gas Valve
Pump connection
Expansion vessel con-
nection
Pump
Pump connection
Pressure gauge
Relief valve
Boiler drain
connection
Facia assembly
Spark electrode lead
Transformer
Earth
connection
Clear tube
(-ve)
Red tube
(+ve)
Water flow
switch
Air flow switch
Fig.46. Spark electrode assembly
Fig.47. Flame sense electrode
Spark
electrode
Notched to aid
location in the fixing bracket
Burner blade
assembly
Fixing bracket
Fixing screw
Spark electrode
assembly
Burner blade
assembly
Fixing bracket
Fixing screw
Flame sense
electrode
Notched to aid
location in the fixing bracket
Flame sense
electrode assembly
NOTE: Cross- lighting
strips are not
shown
NOTE: Cross- lighting
strips are not
shown