Pre-Installation
17
Greenstar 4000 – 6 720 891 162 (2020/09)
4.3.2
Rooms containing a bath or shower
CAUTION
Risk of electric shock
▶ Any switch or appliance control using mains electricity must not be
within reach of a person using the bath or shower.
• In all cases the installation
must be in accordance with the latest
amendments to the latest edition of the IET Wiring Regulations
(BS7671)
.
• Check the IP rating of any control units to be used on this appliance.
• Circuit breaking devices should be used in accordance with the
regulations.
• Figure 12 is for guidance only.
Fig. 12 Bathroom installations
[0]
Zone 0
[1]
Zone 1
[2]
Zone 2
[2*]
Without the end wall, zone 2 must extend 600mm from the bath
[A]
600mm radius from the bath or shower
• Appliance protection rating - IPX4D
• When using a control Key product the boiler rating is maintained at
IPX4D.
4.3.3
Appliance clearances
• The following details cover the installation, service and maintenance
clearances for the appliance.
CAUTION
Risk of damage to appliance or property
The appliance will overheat if the clearance space around the appliance
is restricted by objects.
▶ Do not restrict this space with the addition of cupboards, shelves etc.
next to or around the appliance.
▶ Do not store any combustible materials on or next to the appliance,
such as clothes, towels, paper or plastic bags.
Fig. 13 Appliance minimum clearances
Table 11 Appliance minimum clearances
0010017086-002
2
1
2
1
2
2
1
600mm
600mm
600mm
2250mm
2250mm
2*
A
A
A
600m
m
Minimum clearances
Description
Dimensions (mm)
X
Appliance width
400
Y
Appliance height
724
1)
1) 724mm to middle of top panel.
710mm side panel height.
Bottom panel is removable and not part of minimum clearance height
requirements.
Z
Appliance depth
310
Installation/Maintenance
1
Overall clearance height
1,080/1,120
2)
2) Height for either 60/100 flue or 80/125 flue.
2
Overall clearance depth
760/910
3)
3) Front clearance can be reduced by 150mm, refer to the advice given in Reduced
front maintenance minimum clearances.
3
In front of appliance
450/600
4
Overall clearance width
410
5
Above the appliance
170/210
6
Either side of appliance
5
7
Below the appliance
186
8
Compartment depth
330
9
Appliance to removable door
20
0010012940-001