5
GAS SUPPLY SYSTEM - BASED ON NG (G20)
TOTAL LENGTH OF GAS SUPPLY PIPE (COPPER) metres
3
6
9 12
GAS DISCHARGE RATE - PRESSURE DROP 1mbar. m
3
/h PIPE DIAMETER mm
8.7
5.8
4.6
3.9
22
18.0
12.0
9.4
8.0
28
Table 7
CLEARANCES (mm)
INSTALLATION
SERVICE
ABOVE APPLIANCE AND/OR FLUE ELBOW
30
30
IN FRONT OF APPLIANCE
600
600
BENEATH APPLIANCE
200
200
RIGHT AND LEFT HAND SIDE
10
10
Table 8
SYSTEM CAPACITY
TOTAL SYSTEM VOLUME
litres
INITIAL
INITIAL CHARGE PRESSURE bar
PRESSURE bar
0.5
1.0 1.5
1.0
57
75
N/A
1.5
31
42 52
Table 9
PERFORMANCE SPECIFICATIONS
PRIMARY WATER CAPACITY litres 2.0
MAXIMUM MAINS INLET PRESSURE bar 10
MINIMUM MAINS INLET PRESSURE (WORKING) FOR MAXIMUM FLOW bar 1.3
MINIMUM MAINS INLET PRESSURE (WORKING) FOR OPERATION bar 0.5
DOMESTIC HOT WATER TEMPERATURE RANGE °C 40 - 62
MAXIMUM CENTRAL HEATING FLOW TEMPERATURE °C 82 (nom)
MAXIMUM CENTRAL HEATING SYSTEM SET PRESSURE
bar 2.5
MINIMUM CENTRAL HEATING SYSTEM PRESSURE
bar 0.5
OUTPUT TO DOMESTIC HOT WATER kw NATURAL GAS (G20) 8.5 - 28.0
OUTPUT TO CENTRAL HEATING kw NATURAL GAS (G20) 8.5 - 28.0
DOMESTIC HOT WATER SPECIFIC RATE - 30°C RISE l/min 13.4
MAXIMUM DOMESTIC HOT WATER FLOW RATE - 40°C RISE l/min 10.0
NOx CLASSIFICATION Class 2
SEDBUK NUMBER 78.7
SEDBUK BAND D
Table 5
Refer to Section 6.
DOMESTIC HOT WATER TEMPERATURE RISE
DISCHARGE RATE l/min
7
8
9
10
TEMPERATURE RISE °C
57 50 45 40
Table 6
Summary of Contents for C1
Page 29: ...29 ...
Page 41: ...G C NUMBER 47 311 53 0 I C1 USER INSTRUCTIONS CUSTOMER CARE GUIDE ...
Page 54: ...14 ...