4
28 Sec. Kerosene
0.35 80°S
115
1.10
1.39
165
9.0
3.0
13.3
45500
12
41000
28 Sec. Kerosene
0.5 60°ES
100
1.40
1.77
195
10.5
6.5
16.7
57100
15
51000
28 Sec. Kerosene
0.55 60°ES
120
1.60
2.03
205
11.0
8.0
20
68400
18
61500
35 Sec. Gas Oil*
0.35 80°S
165
1.41
1.66
190
10.5
6.0
16.7
57100
15
51000
35 Sec. Gas Oil*
0.4 80°S
190
1.67
1.96
200
12.5
7.0
20
68400
18
61500
NOMINAL BOILER RATING AT NORMAL OPERATING TEMPERATURE
12/18 Table 2. Bentone Sterling 35 Burner. (See Fig. 22)
Fuel
Nozzle
Pump
Pressure
(p.s.i.)
Fuel Flow
Rate
Flue Gas
Temp.
(°C)**
%CO
2
Approx.
Air
Setting
Appliance
Input
kW
Btu/hr
kW
Btu/hr
Output
Kg/h
l/h
*
NOTE:
for use on conventional flue only.
**
NOTE:
The flue gas temperature is measured in the gas sampling hole on the flue outlet plate. The probe should be inserted to a depth of 50mm. The temperature measured is not an
absolute flue gas temperature and is for general guidance purposes only!
NOTE:
The pump pressure given is for general guidance only as variations in nozzle output can be up to ± 15%. It is, therefore, essential that the air is adjusted to give the correct CO
2
value.
NOTE:
The nozzle type used on 28 Sec. Kerosene outputs are nozzles calibrated specifically for use with 28 Sec. Kerosene which gives less variation in nozzle output than the standard
35 Sec. Gas Oil nozzles. However, if a 28 Sec. Kerosene nozzle is not available at servicing or commissioning it is appropriate to install a 35 Sec. Gas Oil nozzle providing the output, spray
angle and pattern of the nozzle is the same as the 28 Sec. Kerosene nozzle (e.g. 0.75 60°ES may be replaced with a 0.75 60°S).
28 Sec. Kerosene
0.55 60° ES
120
1.60
2.03
170
11.0
6.0
20
64800
18
61500
28 Sec. Kerosene
0.6 60°ES
135
1.89
2.39
190
12.0
7.5
23.9
81700
21.5
73500
28 Sec. Kerosene
0.75 60°ES
115
2.23
2.89
205
12.5
10.0
27.8
95100
25
85500
35 Sec. Gas Oil*
0.40 80°S
190
1.65
1.94
175
11.0
7.0
20
68400
18
61500
35 Sec. Gas Oil*
0.5 80°S
180
2.02
2.38
195
11.5
10.0
23.9
81700
21.5
73500
35 Sec. Gas Oil*
0.55 80°S
175
2.29
2.69
205
12.0
11.0
27.8
95100
25
85500
NOMINAL BOILER RATING AT NORMAL OPERATING TEMPERATURE
18/25 Table 3. Bentone Sterling 40 Burner. (See Fig. 22)
Fuel
Nozzle
Pump
Pressure
(p.s.i.)
Fuel Flow
Rate
Flue Gas
Temp.
(°C)**
%CO
2
Approx.
Air
Setting
Appliance
Input
kW
Btu/hr
kW
Btu/hr
Output
Kg/h
l/h