background image

Energy consumption

 

Greenstar 8000 Style – 6720883869 (2018/05)

14

13

Energy consumption

13.1

Product data on energy consumption

The following product data comply with the requirements of the EU Regulations No. 811/2013, No. 812/2013, No. 813/2013 and No. 814/2013 
supplementing the Regulation (EU) 2017/1369.

Table 9   Product data on energy consumption Greenstar 8000 Style

14

Open Source Software

14.1

List of used Open Source Components

This document contains a list of open source software (OSS) 
components used within the product under the terms of the respective 

licenses. The source code corresponding to the open source 
components is also provided along with the product wherever mandated 
by the respective OSS license.

Table 10  

Provided that within certain OSS-Licenses (e.g. LGPL-2.0) necessary, 
reverse-engineering is allowed for the respective software component to 
the required extent. This shall not apply for other components of the 
software.

14.2

 Used Commercial Source Components

14.2.1 This product contains software developed and licensed by 

SEGGER Software GmbH

Product data

Symbol

Unit

7 738 100 805/854 

7 738 100 837/856

7 738 100 806/855

7 738 100 838/857

Product type

GR8700iW 30 S NG/LPG 

GR8700iW 30 SB NG/LPG

GR8700iW 35 S NG/LPG 

GR8700iW 35 SB NG/LPG

Condensing boiler

Yes

Yes

Rated heat output

P

rated

kW

30

34

Seasonal energy efficiency for central heating

s

%

94

94

Energy Efficiency Class

A

A

Available heat output

At rated heat output and high temperature regime

P

4

kW

29.5

33.7

At 30 % of rated heat output and low temperature regime

P

1

kW

9.9

11.3

Useful efficiency

At rated heat output and high temperature regime

4

%

88.5

88.8

At 30 % of rated heat output and low temperature regime

1

%

98.7

98.8

Auxiliary electricity consumption

At full load

el

max

kW

0.067

0.048

At part load

el

min

kW

0.014

0.013

On standby

P

SB

kW

0.001

0.001

Other items

Standby heat loss

P

stby

kW

0.071

0.071

Ignition burner power consumption 

kWh

0.000

0.000

NOx emissions

NO

x

mg/kWh

23

25

Sound power level, indoors

L

WA

dB

53

53

Name of OSS 
Component

Version of OSS 

Component

Name and Version of License (License text can be found in 

Appendix below)

More Information

STM32cube 
generated files

Unspecified

BSD (Three Clause License) (

 Kap.  14.3.1)

COPYRIGHT©  2016 

STMicroelectronicsCOPYRIGHT©  2014 

STMicroelectronics

STMC4Lib-IAR

Unspecified

BSD (Three Clause License) (

 Kap.  14.3.1)

Copyright ©  2009 - 2015 ARM 

LIMITEDCOPYRIGHT©  2016 

STMicroelectronics

stm32f30x

Unspecified

MCD-ST Liberty Software License Agreement v2 

(

 Kap.  14.3.2)

COPYRIGHT 2012 STMicroelectronics

Summary of Contents for GR8700iW 30 S LPG

Page 1: ...6720883869 2018 05 UK IE User Instructions Gas fired condensing system boiler Greenstar 8000 Style GR8700iW 30 S NG GR8700iW 35 S NG GR8700iW 30 SB NG GR8700iW 35 SB NG...

Page 2: ...re of exceptional quality and proven reliability Our products employ the latest technologies and they are reliable extremely energy efficient offering you economical running costs and value for money...

Page 3: ...water mode 9 4 4 1 Hot water key 9 4 5 Operating the menu 9 4 6 Settings in the menu 9 5 Key accessories 10 5 1 Installing the Key 10 5 2 Key LED 10 5 3 Setting the time program 10 6 Shutdown 11 6 1...

Page 4: ...non permitted use H If you smell gas A gas leak could potentially cause an explosion If you smell gas observe the following rules Prevent flames or sparks Do not smoke use a lighter or strike matches...

Page 5: ...etc within the vicinity of the heat source Do not store or use any corrosive substances solvents adhesives chlorinated cleaning agents etc within the vicinity of the heat source H General consideratio...

Page 6: ...istration card for further details of the Worcester Bosch Group Service Contract When your appliance requires servicing please contact a Worcester Bosch Group contact centre see rear cover appointment...

Page 7: ...result in corrosion within the heating system reducing the efficiency and increasing contaminates Check for leaks on heating system pipe work and radiator valves Contact your installer or maintenance...

Page 8: ...Key accessories auto Heating is switched on and off according to programmed times for heating Advance Switch to Advance to move to the next on or off time and directly switch on or off heating Symbol...

Page 9: ...is on from the first programmed on time to the last programmed off time without programmed intermissions 1 Only available with installed Key accessories Heat time prog 1 Timer for heating Weekday s s...

Page 10: ...and confirm the Time program menu The menu items Mon Fri Sat Sun Mon Sun are displayed Possible items to change Mon Fri for change switching times for all weekdays together Mon Sun to change switchin...

Page 11: ...clearances Your installer will have provided adequate space around the appliance for operation safety and servicing maintenance access Thefollowingdetailthenecessaryclearancearoundtheappliancefor serv...

Page 12: ...ed as text Press the and keys until Reset is displayed The appliance starts up again and the current supply temperature is displayed If a fault persists Contact the contractor or the customer service...

Page 13: ...ol systems Upgrade your heating control system if necessary with the latest equipment available Roof insulation Around30 oftheheatlossfromapropertyisthroughtheroof Replace any old insulation with new...

Page 14: ...GR8700iW 30 S NG LPG GR8700iW 30 SB NG LPG GR8700iW 35 S NG LPG GR8700iW 35 SB NG LPG Condensing boiler Yes Yes Rated heat output Prated kW 30 34 Seasonal energy efficiency for central heating s 94 9...

Page 15: ...terials provided with the distribution 3 Neither the name of STMicroelectronics nor the names of other contributors to this software may be used to endorse or promote products derived from this softwa...

Page 16: ...Kingdom Tel 0330 123 9559 worcester bosch co uk TECHNICAL SUPPORT 0330 123 3366 RENEWABLE SUPPORT 0330 123 9229 CONTROLS AND CONNECTIVITY TEAM 0330 123 3641 APPOINTMENTS 0330 123 9339 SPARES 0330 123...

Reviews: