DESCRIPTIONS

Check for transport damage.
You should be in possession of the following items:
1x MINIDIM 1
1 Manual
Should you discover transport damage after unpacking the
equipment, inform the hauler immediately. Never connect a

DELIVERY PACKET

damaged device. You may also contact your supplier.

TECHNICAL SPECIFICATIONS

Operation temperature

Control Protocol

Dimensions
Weights

-10ºC to +50ºC

DMX-512 (1990)

200g

Power Requirement

12~24 V DC

*Please Note: Improvements and specifications in the design of the unit and the manual are subject to

change without any prior written notice.

OPERATION GUIDE

1.DMX Control Mode(DMX Addressing)

DMX is short for Digital Multiplex.This is a universal binary language used as a form of communication between
intelligent fixtures. Each DipSwitch represents a binary value.

In this mode, the dip-switch 10 is flipped to the"

"position, 11 & 12 IN “OFF”. DMX address can

be addressed using dip 1 to 9  and the intensity of LED production is dimmable.

ON

Read this manual carefully before using our

MINIDIM 1

. As a signal channel dimmer, the 

MINIDIM 1

is a combination of a control interface and tension provider for our 

LEDLINE 100 WHITE

modules as a LED fixture for

application. A maximum of up to 6A loads are allowed on a single output, DMX address enables to be addressed by
flipping the dip-switch.The dimmer is available in DMX Control Mode, Manual Dim Mode and features 0-10V analog
input. The intensity of LED product can be dimmed in the Manual Dim Mode.

Input

2-pin terminal connector for Power In
2-pin terminal connector for Analog In
3-pin terminal connector for DMX In

Output (6AMax.)

3-pin terminal connector for DMX out
4-pin terminal connector for LOAD (Double output)

90(L)x40(W)x20(H)mm

MINIDIM 1                 User Manual/Manual de uso      Page 1

Summary of Contents for MINIDIM 1

Page 1: ...User Manual Instrucciones de Usuario MINIDIM 1 Rev 14 08 01 ...

Page 2: ...epresents a binary value In this mode the dip switch 10 is flipped to the position 11 12 IN OFF DMX address can be addressed using dip 1 to 9 and the intensity of LED production is dimmable ON Read this manual carefully before using our MINIDIM 1 As a signal channel dimmer the MINIDIM 1 is a combination of a control interface and tension provider for our LEDLINE 100 WHITE modules as a LED fixture ...

Page 3: ... switch 1 8 to set the intensity of LED product Each Dip Switch represents a binary value The intensity is set by combining the different dipswitches that will add up to the value you wish to achieve for example Setting the Intensity for 21 Flip switches1 3 5 to the ON position Setting the Intensity for 201 Flip switches1 4 7 8 to the ON position Dipswitches Value 1 1 3 4 5 16 21 Dipswitches Value...

Page 4: ...ara nuestras tiras LED LINE 100 WHITE Una carga máxima de 6A es el valor máximo permitido en la salida El direccionamiento DMX permite direccionar la unidad mediante dipswitches El dimmer dispone de control DMX o Manual suministrando entrada analógica de 0 10 V La insidad de la carga puede ser dimmerizada en modo Manual Compruebe si la unidad ha sufrido daños durante el transporte La unidad debe c...

Page 5: ...1 Un valor DMX Dirección se configura como la combinación de diferentes dipswitches que conforman un valor Un valor de intensidad se configura como la combinación de diferentes dipswitches que conforman un valor obtenido obtenido MINIDIM 1 User Manual Manual de uso Pagina 5 2 Modo dimmerización manual 3 Modo entrada analógica 1 2 3 4 5 6 7 8 9 10 ON OFF 1 0 11 12 Dip Switch 1 address equivale a 1 ...

Page 6: ...EQUIPSON S A Avda El Saler 14 Pol Ind L Alteró 46460 Silla Valencia Spain Tel 34 96 121 63 01 Fax 34 96 120 02 42 www work es support work es ...