background image

Conector AC:   

Junto  con  la  unidad  se  suministra  un  cable  de  alimentación  con  el  conector 

adecuado. Para Se trata de un cable de 3 conductores  y conector con terminal de masa de 15A.

Controles
Interruptor de encendido/apagado: 

El panel frontal dispone de un interruptor usado para encender o apagar el amplificador.

Ganancia

: A En el panel frontal dispone de un potenciómetro rotativo para canal que se usa para 

controlar el nivel de salida.

Stereo/Mono:

AUn  conmutador  de  3  posiciones  situado  en  el  panel  trasero  se  usa  para 

seleccionar el modo de funcionamiento: Stereo, Bridge-Mono o Parallel-Mono.

 

Entrada/Salida

Conector de Entrada: 

Conector XLR balanceado/RCA desbalanceado

Impedancia de entrada

: Nominalmente 20k ohms, balanceado;   10 k ohms, desbalanceado.

Conector de salida: 

2 sets de terminales Bindon Post (rojo/negro) para conectores tipo banana.

Modos de señal de salida
Estereo: 

Balanceada, 2 canales.

Bridge-Mono: 

Balanceada, monocanal. La entrada del canal 1 está activa, ambos controles de 

volumen están disponibles.

Parallel-Mono: 

Balanceada, monocanal. La entrada del canal 1 está activa, ambos controles de 

volumen están disponibles.

                                             14

User Manual/Manual de Uso     WCE 200/400                         

WCE200 

WCE400

Potencia de manejo

8 ohm por canal  

150W 

220W

4 ohm por canal  

220W 

380W

8 ohm modo bridge

500W 

800W

Relación S/N

>65dB 

>67dB

Slew rate

5V/us

5V/us

Factor Damping

300 

300

Modos de funcionamiento

Stereo/Parallel/ Bridge

Stereo/Parallel/ Bridge

Crosstalk

>46dB

>46dB

Retardo de encendido

7 sec

7 sec

Sensibilidad de entrada

0.7V

0.8V

Respuesta en frecuencia 20-20KHz

< +/- 0.25dB

< +/- 0.25dB

Conexionado de entrada

XLR

XLR

Conexionado Link

RCA

RCA

Conexionado de salida

Binding post

Binding post

Soft start

Si

Si

Alimentación

185-245V

185-245V

Dimensiones /AnxPrxAl/ mm

483x277x44

483x277x89

Peso

THD 

0.05% 

0.05%

MODELO

3.7kg

4.5kg

ES

Summary of Contents for WCE 200

Page 1: ...SIG WCE 200 WCE 400 Rev 1 0 User Manual Manual de Uso...

Page 2: ...NSIDE REFER SERVICING T O Q U A L I F I E D S E R V I C E P E R S O N N E L D I S C O N N E C T POWER CORD BEFORE REMOVING REAR PANEL COVER TO ACCESS GAIN SWITCH Shock Hazard Do Not Enter Choc Hasard...

Page 3: ...stallation 2 1 Stereo 4 2 2 Mono 4 2 3 RequiredAC Mains 5 3 Operation 3 1 Precautions 5 3 2 Power Indicator 5 3 3 Protection Systems 6 3 3 1 Drive Protection 6 3 3 2 Signal Limiting Circuit 6 4 Specif...

Page 4: ...acking materials in the unlikely event your unit should ever need to be returned to the factory for service of any kind 1 2 Features Rugged road worthy professional power amplifier E I A Standard 19 4...

Page 5: ...el In Bridge Mono mode the outputs are wired for twice the output voltage In Parallel Mono mode the inputs are paralleled to link the two channels Bridge Mono mode is provided for loads with impedance...

Page 6: ...s selecting signal sources and controlling the output level 4 Do not short the ground lead of an output cable to the input signal ground This will form a ground loop and may cause oscillations 5 Do no...

Page 7: ...fier in Drive Protection mode This mode protects the loads and prevents oscillations The unit resumes normal operation as soon as the amplifier no longer detects dangerous output Although it is extrem...

Page 8: ...s Stereo Balanced two channel Bridge Mono Balanced single channel Channel 1 inputs are active Both channel volume controls are available Parallel Mono Balanced single channel Channel 1 inputs are acti...

Page 9: ...zumbidos El triangulo le alerta del riesgo de descargas El punto de exclamaci n le alerta de una instrucci n importante PRECAUCION 8 User Manual Manual de Uso WCE 200 400 Este s mbolo en su equipo o e...

Page 10: ...nstalaci n 11 2 1 Est reo 11 2 2 Mono 11 2 3 Alimentaci n AC requerida 12 3 Funcionamiento 12 3 1 Precauciones 12 3 2 Indicador de potencia 12 3 3 Protecciones 12 3 3 1 Drive Protection 13 3 3 2 Limit...

Page 11: ...e embalaje para el hipot tico caso en que sea necesario devolver la unidad 1 2 Caracter sticas Robusto amplificador de potencia profesional en formato de 1 HU rack 19 SIG Indicadores Canal 1 Control d...

Page 12: ...n de salida En modo Parallel las entradas se conectan en paralelo El modo Bridge se utiliza para cargas superiores a los4 ohmios y el modo paralelo suele usarse con cargas de 4 ohms Bridge mono 1 Gire...

Page 13: ...n adecuada 3 Use las conexiones con cuidado seleccionando fuentes de se al y controlando niveles de salida 4 No puentee un terminal de masa del cable de salida a un terminal de masa de la entrada Cre...

Page 14: ...ede activarse en dos situaciones Primera si se detectan frecuencias subs nicas peligros o DC en la salida la unidad activar su circuiter a de protecci n DC baja frecuencia la cual pondr el amplificado...

Page 15: ...Post rojo negro para conectores tipo banana Modos de se al de salida Estereo Balanceada 2 canales Bridge Mono Balanceada monocanal La entrada del canal 1 est activa ambos controles de volumen est n d...

Page 16: ...www equipson es EQUIPSON S A Avda El Saler 14 Pol Ind L Alter 46460 Silla Valencia Spain Tel 34 96 121 63 01 Fax 34 96 120 02 42 equipson equipson es...

Reviews: