background image

PowerFLO

 2200 Series

Specifications

Motor 

Type:  12 VDC, permanent magnet, thermally protected, 

splashproof
Leads: 

 

2200-2 Model: 18 AWG, 4.5” long 

Duty Cycle: Intermittent

Pump

Type: 2-chamber positive displacement, self priming, 

capable of being run dry
Liquid Temperature: 110°F (43°C) Max.
Priming Capabilities: 4 feet (1.2 m) suction lift
Max Pressure: 40 PSI (2.8 bar)
Pressure Demand Switch:
Shut-Off: 40 ±5 PSI (2.8 ±0.3 bar) factory setting

 

Turn-On: 25 ±5 PSI (1.7 ±0.3 bar) factory setting
Inlet/Outlet Ports: 3/8” hose barb

3

1

2

Weight

1.25 lbs (0.57 kg)

Performance

Materials of Construction

Motor Housing: Nylon 6/6
Pump Housing: Polypropylene
Valves: Viton
Diaphragm: Santoprene
Fasteners: Stainless steel and zinc plated

Pressure/Flow/Amp Draw
 

PSI  

Bar  

GPM  

LPM  

Amps

 

0-3 

0.2 

1.00 

3.7 

1.5

 

10 

0.7 

0.85 

3.1 

1.9

 

20 

1.4 

0.71 

2.6 

2.1

 

30 

2.1 

0.61 

2.3 

2.4

 

40 

2.8 

0.42 

1.6 

2.6

Parts List

Ref 

  

Part 

 

Description

 

Number

1

 

Switch Asssembly

 

5157201

2

 

Pump Head wSwitch Asssembly

 

5275064

3

 

Motor

 

  with connector,  no switch

P39-045B

Dimensions

Inches (mm)

2.25

(57)

6.89

(175)

1.66

(42)

2.55

(65)

3.94

(100)

1.58

(40)

1.73

(44)

4.5

(114)

Manual ON/OFF

Switch with Protective Cover

(2200-30... Models only)

Pressure

Demand Switch

3.19

(81)

3/8 (9.5)

Hose Barb Port(s)

9

(228)

Leadwires:

(2200-10...

Models only)

2-Pin Connector:

(2200-20...,

2200-30...

Models only)

18 AWG Leadwires:

Blk – Negative

Red – Positive

PRECISION SPRAY EQUIPMENT, a divison of Green Leaf, Inc.   9490 N BALDWIN ST   FONTANET, IN 47851   www.grnleafinc.com   800-654-9808

a division of Green Leaf, Inc

®

P R E C I S I O N   S P R AY   E Q U I P M E N T

PSE

®

Summary of Contents for LG25 ESS

Page 1: ...Flush with water to clear any accumulated debris These sprayers are designed to be attached to a stable surface The purpose of this manual is to assist you in assembling operating and maintaining your lawn and garden sprayer Please read it carefully as it furnishes information which will help you achieve years of dependable trouble free operation After use fill the sprayer part way with water Star...

Page 2: ...er Assembly 600155 1 7 8 Spray Wand Clip 600151 2 18 5 mm Diameter Pinch Clamp 600149 3 9 Lead Wire Assy w Switch 96 600153 1 10 10 24 3 8 Pan 600152 2 11 Rubber Grommet 600207 1 12 15 Gallon Tank 600239 1 13 Economy Wand Hose Assembly 600261 1 14 1 0 GPM Pump w Barbed Fittings 630011 1 15 10 24 x 3 4 Truss Head Screw 630014 4 16 PRECISION SPRAY EQUIPMENT a divison of Green Leaf Inc 9490 N BALDWIN...

Page 3: ...ners Stainless steel and zinc plated Pressure Flow Amp Draw PSI Bar GPM LPM Amps 0 3 0 2 1 00 3 7 1 5 10 0 7 0 85 3 1 1 9 20 1 4 0 71 2 6 2 1 30 2 1 0 61 2 3 2 4 40 2 8 0 42 1 6 2 6 Parts List Ref Part Description Number 1 Switch Asssembly 5157201 2 Pump Head wSwitch Asssembly 5275064 3 Motor with connector no switch P39 045B Dimensions Inches mm 2 25 57 6 89 175 1 66 42 2 55 65 3 94 100 1 58 40 1...

Page 4: ...ine fuse and or fuse in car adapter end Ensure correct voltage 10 12 13 volt Low flow or no flow at all what should I check Check for a clogged suction hose and or suction strainer Often you will need to clean the suction strainer Check for proper voltage Is there a fuse for the sprayer Yes either an in line fuse a fuse located in the car adapter housing or both What size fuse should I use as a re...

Reviews: