7. SYSTEM ASSEMBLY
7
System assembly
7.1 Connection
For fully controlling the SAFETIS you need:
Ethernet Cable
1x M12 5‐pin cable for power supply (Safetis indoor only)
1x M12 8‐pin cable for Digital Outputs
7.1.1 Power Supply
7.1.1.1 SAFETIS Indoor Power Supply
You can power your SAFETIS with M12 5‐pin cable. Voltage between VCC and GND pins must be within range
18VDC ‐ 32VDC
. You can see the power connector pinout in the Figure 7.1a.
(a) Power supply connector
pinout.
Contact
Function
Color
1
VCC+
Brown
2
VCC+
White
3
GND
Black
4
GND
Blue
5
NC
Gray
(b) Power supply wire coloring.
Note
: Exceeding the input power range may cause damage to the SAFETIS.
SAFETIS Indoor has power consumption 10W.