6. SYSTEM ASSEMBLY
6
System assembly
6.1 Connection
For fully controlling the SMARTIS you need:
Ethernet Cable
1x M12 5‐pin cable for power supply
3x M12 8‐pin cables for Digital Triggers, Digital Outputs and Analog Outputs
6.1.1 Power Supply
You can power your SMARTIS with M12 5‐pin cable. Voltage between VCC and GND pins must be within range
18VDC ‐ 32VDC
. You can see the power connector pinout in the Figure 6.1a.
(a) Power supply connector
pinout.
Contact
Function
Color
1
VCC+
Brown
2
VCC+
White
3
GND
Black
4
GND
Blue
5
NC
Gray
(b) Power supply wire coloring.
Note
: Exceeding the input power range may cause damage to the SMARTIS.
6.1.2 Digital Triggers
You can trigger your SMARTIS with M12 8‐pin cable. Trigger level of each trigger is within range
8VDC ‐ 36VDC
.
You can see the trigger connector pinout in the Figure 6.2a.