10. OPERATOR MODE
After the frame grabbing is finished and measurement is evaluated, the graph and thermocamera image are
updated.
The thermocamera image shows the frame with the ”worst” result ‐ the biggest difference between the critical
value and ROI frame statistic among all ROIs. This is the most important frame for evaluating fail states.
The graph shows all the selected ROI statistic results for all frames in the measurement. The displayed frame is
marked with a dot in the graph.
Special case is when the measurement sequence consists only of one frame. Then the image displays this frame
and the graph shows the development of frame statistic result value in time.
Start‐Stop Measurement
Start‐Stop measurement takes number of frames according to digital input signals, from which it calculates the
measurement results. It starts to grab the frames when either digital Latch or Start signal is detected and stops
when Latch signal stops or the Stop signal is detected.
Thus the digital input Latch or Start‐Stop and IC are enabled.
After the frame grabbing is finished and measurement is evaluated, the graph and thermocamera image are
updated.
The thermocamera image shows the frame with the ”worst” result ‐ the biggest difference between the critical
value and ROI frame statistic among all ROIs. This is the most important frame for evaluating fail states.
The graph shows all the selected ROI statistic results for all frames in the measurement. The displayed frame is
marked with a dot in the graph.
Continuous Measurement
Continuous measurement takes one frame at a time with selected period according to settings, from which it
calculates the measurement results. It starts to grab the frame when either digital Latch or Start signal is detected
and stops when Latch signal stops or the Stop signal is detected.
Thus the digital input Latch or Start‐Stop and IC are enabled.
Since each measure sequence consists only of one frame, the image shows this frame and graph shows the ROI
frame statistic results development. Each new result is added to the graph.
Non‐Trigger Measurement
Non‐Trigger measurement takes each one frame from which it calculates the measurement results. It takes every
frame regardless of digital inputs.
Thus only the digital input IC is enabled.
The image shows the video stream and graph shows the ROI frame statistic results development. Each frame
result is added to graph.