Check whether the mains voltage corresponds to the electrical data
on the rating plate (Fig. 10); the maximum permitted deviation is 5%.
•
Set the On/Off switch (3) on the top half of the device to the “OFF”
position (press in) (Fig. C).
•
Put the plug into the socket and switch the On/Off switch (3) to
“ON” (pull out) to start up the compressor. The compressor is fully
automatic. It is controlled by the pressure switch, which stops
the compressor if the pressure in the tank reaches the maximum
value and restarts it as soon as the pressure falls to the minimum
value. Normally the difference in pressure between the maximum
and minimum values is approximately 2 bar/29 psi. Example: The
compressor stops working as soon as it reaches 8 bar (116 psi) (max.
operating pressure) and restarts automatically when the pressure in
the tank falls to 6 bar (87 psi).
•
After connecting the compressor to the power supply, fill the tank
with air at maximum pressure and check that the device is working
properly.
The assembly consisting of head/cylinder/air line can reach high
temperatures, so take care when working near to these parts and
refrain from touching them in order to avoid burn injuries.
Quick connect coupler (Fig. A, 6): This coupler establishes the connection
to the regulated output pressure. Push the coupler in to connect the air
hose. To disconnect the air hose, pull back the coupler collar and detach
the coupling.
Tank pressure gauge (Fig. A, 8): This measuring instrument measures the
pressure of the air stored in the tank. It cannot be set by the operator and
it does not indicate the line pressure.