Frequently asked questions
Air loss
•
May be caused by a badly sealed connection.
•
Check all connections by wetting them with soapy water.
Compressor will not start
If the compressor fails to start easily, then check the following:
•
Does the mains voltage match the voltage shown on the rating plate?
•
Has an extension cable with the wrong cross-section or length been
used?
•
Is the work area too cold (below 0° C)?
•
Is there oil in the crankcase to provide adequate lubrication (Fig. I)?
•
Is the power supply working (plug properly inserted, overload
protection not triggered, fuses not defective)?
Compressor will not stop
The tank safety valve is activated if the compressor does not stop when it
reaches maximum pressure. Contact your nearest authorized service cen-
tre to have the device repaired.