ECRESO FM 5kW / 10kW, user manual
–
11/2021
Page 104
WorldCast Systems SAS - 20 avenue Neil Armstrong - 33700 Mérignac (Bordeaux Métropole) FRANCE
+33 (0)5 57 928 928
–
www.worldcastsystems.com
–
contact@worldcastsystems.com
NAME
Access
(R/W)
Possible value on the serial
port of the unit
Comments
Module
SYS.HARDREL
R
xx.xx.xx x=[0..9]
Hardware version: example "3.0.1"
ECU
SYS.INIT
R/W
XXXX ; X=[0…F]
Reinitialization flag. b0=complete reset
b1=SYS.PASSWORD_RST
ECU
SYS.IP.ADR
R/W
XXX.XXX.XXX.XXX X=[0…9]
IP address of the IP board
ECU
SYS.IP.AUTONEG
R/W
"ON" or "OFF"
Enables/disables auto-negotiation
ECU
SYS.IP.DUPLEX
R/W
"HALF" or "FULL"
Ethernet communication mode
ECU
SYS.IP.GW
R/W
XXX.XXX.XXX.XXX X=[0…9]
Network gateway of the IP board
ECU
SYS.IP.MAC
R
XX:XX:XX:XX:XX:XX:XX:XX
X=[A..F;0..9]
Mac address of the IP board
ECU
SYS.IP.MASK
R/W
XXX.XXX.XXX.XXX X=[0…9]
IP mask of the IP board
ECU
SYS.IP.SPEED
R/W
"10" or "100"
Ethernet communication speed
ECU
SYS.KEY.ADD
R/W
ADD
Generates a key to enable the specified option
ECU
SYS.KEY.RDS_STATIC
R
Gives the remaining time on a temporary RDS
license
ECU
SYS.KEY.REM
R/W
REM
Generates a key to disable the specified option
ECU
SYS.KEY.SFM
R
Gives the remaining credit on a SmartFM license
ECU
SYS.KEY.SOUND_PRO
C
R
Gives the remaining time on a temporary Sound
Processing license
ECU
SYS.LANG
R/W
"FR" or "EN" or "ES" or "DE"
or "RU"
Selects the front panel application language
ECU | DRVn
SYS.LCDMENUS
R/W
"NORMAL" or "ADVANCED"
Sets the display type on the front panel screen,
Easy or Expert
ECU | DRVn
SYS.LOCALCOM.ECHO
R/W
"ON" or "OFF"
Adds the local echo on the front panel serial port
ECU
SYS.LOCALCOM.SPEE
D
R/W
9600,19200,38400,57600,1
15200
Speed of the front panel serial port
ECU
SYS.LOG
R
List of the latest 200 events (configuration
changes, alarm start date and end date…)
DRVn
SYS.LOG.CLR
W
Clears the event list
DRVn
SYS.MEMORY
R
"PRES" or "NOT PRES"
Indicates if the optional memory required for
SFN is present
ECU
SYS.NAME
R/W
XXXX X=[A…Z]
Equipment name
ECU | DRVn
SYS.OPT.LIST
R
GPIO_STD, GPIO_ANA,
RF_PROBE, IP, COM_STD,
MPX_IN, AUDIO_IP, TUNER,
RDS_STATIC,
RDS_DYNAMIC,
POWERFUL_CONTROL
List of implemented options
ECU | DRVn
SYS.PASSWORD
R/W
xxx x=[A..Z;0..9]
Password for the console and front panel display.
‘NONE’ disables the password
DRVn
SYS.PASSWORD.RESE
T
R/W
xxx x=[A..Z;0..9]
Creates a text string to unlock the password if it
has been forgotten
ECU
SYS.PAVL
R
[0..9999]
Max power, set in factory and limited depending
on the type of unit. This limitation can be
requested by regulating agencies.
ECU
SYS.PCAP
R
[0..999]
Nominal power of the unit: example "300"=>300
W
ECU
SYS.RAZ
W
"RAZ"
Reloads default values. With an IP unit,
wait for
IP connection to be available before shut off
.
ECU
SYS.RST
W
Reset of all parameters.
ECU | DRVn |
PAn | PSUn
SYS.RST.CPU
W
"RST"
General reset of the µc. Sends the return code:
RST
ECU | DRVn |
PSUn
SYS.RST.EXCHW
W
"RST"
Material restart of the exciter card
ECU | DRVn
SYS.SDC.EJECT
R/W
"YES" or "NO"
Request the removal of the µSD card. This
command can only be sent locally.
ECU | DRVn