NAME
Access
(R/W)
Possible value
on the serial
port of the unit
Comments
RDS.VOTE.CENTER.STR
R/W
[A…Z]
Sets the command that modifies <VOTE.CENTER>; default
value: VOTECENTRE
RDS.VOTE.QUESTION.STR
R/W
[A…Z]
Sets the command that modifies <VOTE.QUESTION>; default
value: VOTEQUESTION
RT.TEXT
R/W
ascii
[0x21…0x7E]
Dynamically sets the radiotext with Tags <ITEM.TITLE>,
<ITEM.ARTIST>, …Equivalent to the command RDS.RT1.TEXT
7.2.9.
ACU commands
These commands only apply to the control unit.
NAME
Access
(R/W)
Possible value on the serial port
of the unit
Comments
ACU.CURRENT_MAIN
R
"1" or "2"
Indicates the current MAIN transmitter
ACU.DELAY
R/W
[0…99] sec
Delay between error detection and switch
ACU.DELAY.START
R/W
[0…99]
Module start delay in seconds. Default value: 10.
ACU.DELAY.SWITCH
R/W
[0…99]
Delay after switching in seconds (0 for 1+1, 4 for DD).
ACU.FAULT
R
"FAULTY" or "OK"
Fault state of the switch-over unit
ACU.ITER.CONF
R/W
[0…99]
Set the max number of switch on the reserve transmitter
(or drive)
ACU.ITER.MEAS
R
[0…99]
Gives the number of switches to the reserve transmitter
(or drive)
ACU.OPERATION
R/W
"AUTO" or "MANU"
Sets the switch to auto or manual switching mode
ACU.POS
R
"1" or "2"
Gives the switch position
ACU.PRESELECT
R/W
"1" or "2"
Set the main transmitter (or drive)
ACU.READY
R
"READY" or "NOTREADY"
State of the reserve switch-over unit
ACU.RESERVE_CONTROL
R/W
"ON" or "OFF"
Operation mode of the reserve exciter/transmitter
ACU.SWITCHOVER
R
"ON" or "OFF"
Indicates if switching occurred
ACU.SWLAST
R
Remembers the reasons for the last switch
ACU.SWNOCOMM
R/W
"ON" or "OFF"
ON=switching is authorized on loss of communication
with the main transmitter.
ACU.SWONFAULT
R/W
"ON" or "OFF"
ON= switching is authorized if the reserve transmitter is
in fault.
ACU.VSWRINHIB
R
"ON" or "OFF"
"ON" a VSWR fault will not trigger a switch. OFF: switch
on VSWR fault.
7.2.10.
Status commands
NAME
Access
(R/W)
Possible value on the serial
port of the unit
Comments
Modules
STAT.10M
R
"PRES" or "NOT PRES"
Indicates the presence of an external 10
MHz
ECU | DRV
n
STAT.1PPS
R
"LOCK" or "UNLOCK"
Indicates the presence of an external 1
PPS
ECU | DRV
n
STAT.ALIM.CONFG
R
0,1 or 2
Number of additional optional PSU
ECU
STAT.CLK
R
"INTERNAL" or "EXTERNAL" Indicates the 10 MHz switch position
ECU | DRV
n
STAT.COMM
R
"ON" or "OFF"
Status of the communication between
the control unit and the selected
module
DRV
n
| PA
n
|
PSU
n
STAT.CURRENT.IN
R
"1+OPT" or "1+2" or "2+OPT"
Indicates the channels used for channels
1 and 2
DRV
n
STAT.DCOK1
R
"ON" or "OFF"
Indicates if the PSU 1 of the amplifier is
"ON" or "OFF"
DRV
n