8.6.8.
SNMP Agent
Path:
System
/SNMP/SNMP Agent
SNMP parameters are on both the SNMP Agent page and the SNMP Manager page.
▪
SNMP
Minutes between Heartbeats:
sends the heartbeat every X minutes. This trap makes it possible to check that the unit
is connected to the network.
Local ports:
set the ports on which the traps are sent.
GET / SET communities:
Set whether a community is private or public. GET 2 and SET 2 communities can be
used for a second manager (up to four managers can be set, see next section) or for test and
maintenance.
Max pending traps:
set the number of traps in the manager queue, between 255 and 1000.
MIB:
to download the MIBs click on the button. The mibs.zip file includes the Ecreso MIB and the IRT MIBs.
▪
SNMP Traps
Trap sending test:
enables the user to carry out a test according to the trap settings.
Signal suppression in local mode:
•
If the box is checked, as soon as the transmitter is in local mode, SNMP GET return the value
undefined and SNMP traps are no longer sent. SNMP traps start being sent again when the
transmitter is no longer in local mode.
It is useful to prevent generating traps while in maintenance.
•
If the box is not checked, SNMP GET return the current value and traps are sent even in local
mode.
If the transmitter is part of an N+1 system with Ecreso N+1, this mode must be disabled to ensure the system will
work properly.