ECRESO FM 5kW / 10kW, user manual
–
11/2021
Page 186
WorldCast Systems SAS - 20 avenue Neil Armstrong - 33700 Mérignac (Bordeaux Métropole) FRANCE
+33 (0)5 57 928 928
–
www.worldcastsystems.com
–
contact@worldcastsystems.com
10.2.2.
Remote control function pinout
Function
Remote Control
Input name
Common
POWER ON
RC1
OPT1A(20)
RC_COMMUN(24)
POWER OFF
RC2
OPT2A(8)
RC_COMMUN(24)
RF ON
RC3
CONF1(21)
RC_COMMUN(24)
RF OFF
RC4
CONF2(9)
RC_COMMUN(24)
TA_ON* or PRESELECT 1
+
RC5
CONF3(22)
RC_COMMUN(24)
TA_OFF* or PRESELECT 2
+
RC6
CONF4(10)
RC_COMMUN(24)
MAIN* or AUTO MODE
+
RC7
CONF5(23)
RC_COMMUN(24)
ALT*or MANUAL MODE
+
RC8
CONF6(11)
RC_COMMUN(24)
Numbers in parenthesis indicated the pin number on the DB25 connector.
* In simple drive.
+ ACU default configuration
10.2.3.
Remote monitoring function pinout
Event
Remote Monitoring
Output name
Common
LOCAL
RM1
REL1_RT(1)
REL1_C(14)
FAULT
RM2
REL2_RT(2)
REL2_C(15)
WARNING
RM3
REL3_RT(3)
REL3_C(16)
RF ON* or SWITCHOVER
or RESERVE OK
+
RM4
REL4_RT(4)
REL4_C(17)
ON* or PRESELECT 1
+
RM5
REL5_T(18)
REL5_C(6)
OFF* or PRESELECT 2
+
RM6
REL5_R(5)
REL5_C(6)
VSWR* or AUTO
+
RM7
REL6_RT(19)
REL6_C(7)
Numbers in parenthesis indicated the pin number on the DB25 connector.
* In simple drive.
+ ACU default configuration