DSN alt: enables the alternative DSN (basic RDS) - in simple drive / Manual mode: switches to manual mode
–
in dual-drive
•
Fault reset: reset the fault output
Control commands can also be used to trigger presets. See section 8.4.2 for more details.
Outputs are relays that include a normally closed or normally open contact. When an event occurs in the unit, the
corresponding relay is activated.
Six monitoring functions are associated with relays:
•
Remote: indicates if the transmitter is in remote mode
•
On/Off: indicates if the transmitter is in sleep mode
•
RF On: indicates if the RF enabled
•
RF Off: indicates if the RF is disabled
•
Warning: indicates an alarm
linked to the internal working of the transmitter (temperature, voltage…)
•
Fault: indicates a transmitter fault
10.4.2.
Remote control function pinout
Function
Remote Control
Input name
Common
POWER ON
RC1
ST_CONFIG5(7)
TC_COMMUN(13)
POWER OFF
RC2
ST_CONFIG6(20)
TC_COMMUN(13)
RF ON
RC3
ST_RF_ON(6)
TC_COMMUN(13)
RF OFF
RC4
ST_RF_OFF(4)
TC_COMMUN(13)
TA_ON* or PRESELECT 1
+
RC5
ST_CONFIG1(5)
TC_COMMUN(13)
TA_OFF* or PRESELECT 2
+
RC6
ST_CONFIG2(8)
TC_COMMUN(13)
MAIN* or AUTO MODE
+
RC7
ST_CONFIG3(6)
TC_COMMUN(13)
ALT*or MANUAL MODE
+
RC8
ST_CONFIG4(9)
TC_COMMUN(13)
FAULT RESET **
RC9
ST_FAULT_RESET(3)
TC_COMMUN(13)
Numbers in parenthesis indicated the pin number on the DB25 connector.
* In simple drive.
+ ACU default configuration
** When the transmitter is in fault, it stays in that state until a fault reset (bistable relay).
10.4.3.
Remote monitoring function pinout
Event
Remote Monitoring
Output name
Common
REMOTE
RM1
REL_REMOTE_RT(8)
REL_REMOTE_COM(1)
FAULT
RM2
REL_FAULT_RT(10)
REL_FAULT_COM(2)
WARNING
RM3
REL_WARNING_RT(23)
REL_WARNING_COM(12)
RF ON
RM4
REL__RF_OFF_T(9)
REL_RF_OFF_COM(4)