2.12.
Cooling systems
ECRESO FM 5kW/10kW transmitters are supplied with a ventilation
system adapted to the site configuration: cold air can be retrieved
from the room, at the bottom or at the top, and hot air can be
expelled from the top or from the bottom. A version of the
transmitter is also available where an external cooling system is
required.
In order to provide maximum uptime, a redundant air cooling
configuration can be provided. Two additional fans can thus be
added at the top input and output.
All fans are enslaved to the system temperature: the loss of one fan
does not impact overall temperature.
Top-top configuration
Adapter for bottom inlet or outlet
Configurations
Constraints
Extractor specifications
Cold air taken from
the room / Hot air
evacuated on top
(Room-Top)
The air inlet must be clear.
If hot air is evacuated through a pipe longer than
5 m, an additional fan is required.
927 m
3
/h and 200 hPa on the air
inlet and outlet.
For airflow systems common with N
transmitters: N x 927 m
3
/h and
200 hPa on the air inlet and outlet
Cold air taken from
the top or the
bottom / Hot air
evacuated on top
or on the bottom
(Bottom-Bottom /
Bottom-Top / Top-
Bottom / Top-Top)
If cold air comes from a piper longer than 5 m, an
additional fan is required.
If hot air is evacuated through a pipe longer than
5 m, an additional fan is required.
An adapter is supplied for bottom inlet and/or
outlet. Plan for a sufficiently large hole under the
transmitter to accommodate the installation:
•
Inlet and outlet: 55 x 42 cm
•
Inlet or outlet : 30 x 42 cm
927 m
3
/h and 200 hPa on the air
inlet and outlet.
For airflow systems common with N
transmitters: N x 927 m
3
/h and
200 hPa on the air inlet and outlet
External cooling
Additional top-top external fans are required.
927 m
3
/h and 200 hPa on the air
inlet and outlet for each
transmitter.