ECRESO FM 5kW / 10kW, user manual
–
11/2021
Page 42
WorldCast Systems SAS - 20 avenue Neil Armstrong - 33700 Mérignac (Bordeaux Métropole) FRANCE
+33 (0)5 57 928 928
–
www.worldcastsystems.com
–
contact@worldcastsystems.com
3.
TECHNICAL SPECIFICATIONS
3.1.
Environmental
Nominal operating temperature
5°C to 45°C
Maximum operating temperature
0°C to 50°C
Warehousing temperature
-20°C to +70°C
Humidity
5 - 95 % non-condensing relative humidity
Altitude
Non-redundant version
up to 2900 m
Redundant version
up to 3900 m
Warehousing time
< 10 years
Cooling
Control unit
Internal ventilation (fanless)
FM exciter
Between 10 l/s and 30 l/s depending on ambient temperature
2000W FM amplifier
Internal ventilation
Fan
Max: 927 m
3
/h for each fan module
3.2.
Power supply
Voltage
400 V ±15% 3 W + N + PE
Frequency
50 Hz - 60 Hz
Transmitter typical average consumption
ECRESO FM 5kW
6 800 W
ECRESO FM 10kW
13 500 W
Power factor
> 0.95
Control Unit fuses
4 x 1.6 AT
Driver fuses
10 AT
Amplifier fuses
2 x 50 A
3.3.
Physical
Slave FM exciter
Overall dimension
19’’ (482.6 mm) X 2U (89 mm) X 470 mm
Rack size without front panel
440.4 X 82 X 466.5 mm (WxHxD)
Weight:
around 6.5 kg
2000W FM amplifier
Overall dimension
380 mm X 2U (133.5 mm) X 470 mm
Weight
around 13 kg
Filter
Weight
around 12 kg