ECRESO FM 5kW / 10kW, user manual
–
11/2021
Page 59
WorldCast Systems SAS - 20 avenue Neil Armstrong - 33700 Mérignac (Bordeaux Métropole) FRANCE
+33 (0)5 57 928 928
–
www.worldcastsystems.com
–
contact@worldcastsystems.com
SWITCH DELAY
With this parameter, set the delay after a switch. This delay should be set according to the type of system. Default: 4
seconds.
From 0 to 99 s
START DELAY
With this parameter, set the start delay in seconds. This delay insures the system stability. Default: 10 seconds.
From 0 to 99 s
VSWR INHIB
With this parameter, set whether a VSWR fault trigger a switch (off) or not (on).
ON or OFF
SWITCH ON FAULT
With this parameter, set whether a switch can occur when the reserve transmitter or drive is in fault (on).
ON or OFF
SW ON NO COMMUNICATION
With this parameter, set whether a loss of communication with the main transmitter or drive triggers a switch (on).
ON or OFF
5.6.
SmartFM parameters
These parameters are available as:
Front panel
SMARTFM menu
see section 6.3.6
Serial commands
MEAS, TX, CONF, STAT
see sections 7.2.2, 7.2.3, 7.2.4
and 7.2.10
Embedded web site
Transmitter/Main/SmartFM page
see section 8.4.2
* Parameters followed by a star (*) are not available on the front panel.
SmartFM is a worldwide patented technology developed by WorldCast Systems.
SmartFM is an option. If the license is not present, the function cannot be enabled.
SmartFM is the first artificial intelligence dedicated to the FM radio listener experience. SmartFM can:
•
Reduce FM Operating Costs (Opex)
o
Reduces electrical consumption by up to 40%
o
Reduces cooling costs by up to 45%
o
Increases transmitter lifespan
o
Reduces maintenance
•
Reduce CO
2
emisions
o
Measurable and logged benefits
o