7.2.
ECRESO FM serial commands
Commands related to options are only available when the option is present.
7.2.1.
System commands
NAME
Access
(R/W)
Possible value on the serial
port of the unit
Comments
Module
LOGIN
R/W
XXXX,X=[0…z] "LOGGED" or
"NOT LOGGED"
Logs the user and allows them to update
variables if the password is correct. Returns
Logged or not logged
ECU
LOGOUT
W
Logs out the user and locks all variables.
ECU
SYS.ALIM_CONFIG
R
0,1 or 2
Number of additional optional PSU
ECU | DRVn |
PAn
SYS.CID
R/W
[0..31]
Unit identifier used by the CAN bus.
ECU | DRVn
SYS.COM1.ECHO
R/W
"ON" or "OFF"
Adds the local echo on the rear panel serial port
ECU
SYS.COM1.SPEED
R/W
9600,19200,38400,57600,1
15200
Speed of the rear panel serial port 1
ECU
SYS.COM2.ECHO
R/W
"ON" or "OFF"
Adds the local echo on the rear panel serial port
ECU
SYS.COM2.SPEED
R/W
9600,19200,38400,57600,1
15200
Speed of the rear panel serial port 2
ECU
SYS.DATE
R/W
DD/MM/YY
Reads and sets the amplifier date
ECU
SYS.DATECALIB
R
DDMMYYYY
Date of the last calibration
ECU
SYS.DIGMPX
R/W
"YES" or "NO"
Sets the input type for LINE2. NO= LINE2 as audio
input; YES= LINE2 as MPX input
ECU
SYS.EXC
R/W
INTERNAL or EXTERNAL
Allows using drivers which are not managed by
the control unit (external)
!
Warning: using an external driver may
damage the transmitter.
ECU
SYS.FAN_CONFIG
R
0 or 1
Indicates the number of fans. 0: 1 fan IN and 1
fan OUT; 1: 2 fans IN and 2 fans OUT
ECU
SYS.GPIO.CONF1
R/W
"AMB" or "FAN1" or "VOLT"
or "HEAT" or "FAN2" or
"CURRENT" or "PWR"
Sets the RC ANA3 on an analog GPIO board.
Note: CURRENT returns the sum of all currents
on a 400 A scale.
ECU
SYS.GPIO.CONF2
R/W
"AMB" or "FAN1" or "VOLT"
or "HEAT" or "FAN2" or
"CURRENT" or "PWR"
Sets the RC ANA4 on an analog GPIO board.
Note: CURRENT returns the sum of all currents
on a 400 A scale.
ECU
SYS.GPIO.IN.ACT
R
XX X=[A..F;0..9]
Indicates the corresponding RC when assigned to
an external unit.
ECU
SYS.GPIO.IN.MASK
R/W
XX X=[A..F;0..9]
Sets the RC control either by the control board or
by an external unit (IP board). Hexadecimal code:
each bit corresponds to an input. Ex: A1
(10100001) indicates the RC 1, 6 and 8 are
assigned to the IP board.
ECU | DRVn |
PAn
SYS.GPIO.OUT.ACT
R/W
XX X=[A..F;0..9]
Enables the corresponding RM when controlled
by an external unit.
ECU | DRVn |
PAn
SYS.GPIO.OUT.MASK
R/W
XX X=[A..F;0..9]
Sets the RM control either by the control board
or by an external unit (IP board). Hexadecimal
code: each bit corresponds to an input: Ex: 21
(00100001) indicates RM 1 and 6 are controlled
by the IP board.
ECU
SYS.GPIO.RM4
R/W
"RESERVE
OK","SWITCHOVER","RF
ON"
Configuration of relay 4
ECU
SYS.GPIO.RM5
R/W
PRESELECT 1,"ON"
Configuration of relay 5
ECU
SYS.GPIO.RM6
R/W
PRESELECT 2,"OFF"
Configuration of relay 6
ECU
SYS.GPIO.RM7
R/W
AUTO,"VSWR"
Configuration of relay 7
ECU